16
DS861PP3
CS5346
SWITCHING CHARACTERISTICS - CONTROL PORT - I²C FORMAT
Inputs: Logic 0 = DGND = AGND = 0 V, Logic 1 = VLC, C
L
= 30 pF.
13. Data must be held for sufficient time to bridge the transition time, t
fc
, of SCL.
Parameter
Symbol
Min
Max
Unit
SCL Clock Frequency
f
scl
-
100
kHz
RST Rising Edge to Start
t
irs
500
-
ns
Bus Free Time Between Transmissions
t
buf
4.7
-
µs
Start Condition Hold Time (prior to first clock pulse)
t
hdst
4.0
-
µs
Clock Low time
t
low
4.7
-
µs
Clock High Time
t
high
4.0
-
µs
Setup Time for Repeated Start Condition
t
sust
4.7
-
µs
SDA Hold Time from SCL Falling
t
hdd
0
-
µs
SDA Setup time to SCL Rising
t
sud
250
-
ns
Rise Time of SCL and SDA
t
rc
, t
rd
-
1
µs
Fall Time SCL and SDA
t
fc
, t
fd
-
300
ns
Setup Time for Stop Condition
t
susp
4.7
-
µs
Acknowledge Delay from SCL Falling
t
ack
300
1000
ns
t buf
t hdst
t
low
t
hdd
t high
t sud
Stop
Start
S D A
S C L
t irs
RS T
t hdst
t rc
t fc
t sust
t susp
Start
Stop
Repeated
t rd
t fd
t ack
Figure 5. Control Port Timing - I²C Format