3.2.- EMPLACEMENT
When installing the unit it is necessary to respect some minimum distances for maintenance
and safety reasons.
The recommended
LA
height is
:
Minimum value:
600 mm.
Maximum
value:
1200 mm.
Please comply accordingly to your country specifications.
300 mm
300 mm
300 mm
LA
Figure 1:Emplacement�
3.3.- ELECTRICAL WIRING
Before starting with the wiring connection of the charging station, you must take
into consideration this section.
3�3�1�- eHome POWER SUPPLY
Not all models include elements for electrical protection.
The power supply line which comes from the distribution board to the charging point, must meet
the electrical safety standards, according to your country regulations. The minimum safety re-
quired protections are as follows:
RCD
: Type A. IΔ
N
= 0.03 A.
Note:
It is not necessary for models that already include protection internally:
eHome
T2C32-A
,
T2C32-B
,
T2C32-A MID
,
T1C32-A
,
T1C32-B
,
T1C32-A MID
.