32
eHome
Instruction Manual
PENDIENTE DE V
ALIDACIÓN
Tabla 13 (Continuation) : Operating errors�
Error
LEDs bar
Temperature error
When the device temperature is below or above a certain value, it is
detected by the device.
In the meantime, if the device is supplied with heater (optional), it
starts heating the inside components until the operating temperature
is reached. Then the device starts charging again.
Orange, blink
sequence
(1)
According to
IEC IEC 61851.
4.5.- CURRENT LIMIT SELECTOR
There is an onboard rotative DIP switch
to configure the limit current of the device, which has to
be set up according to the model of
Wallbox eHOME
we are going to install.
Be sure that the position of the current limit selector is setup according to the
output current of your device.
Figure 34:DIP switch�
On the
Table 14
is shown the different values available for this current limit selector:
Table 14: DIP switch, position
Position
Limit current
Position
Limit current
0
Not used
5
20 A
1
6 A
6
32 A
2
10 A
7
Not used
3
13 A
8
Not used
4
16 A
9
Not used