29
Command code & return value Function
Example
Input Command:
GETD
[CR]
Return value:
<voltage><current><status>[CR]
OK[CR]
Get PS Display values of Volt-
age, Current and Status of
CC/CV
<voltage>=????
<current>=????
<status>=0/1 (0=CV, 1=CC)
Input command:
GETD
[CR]
Return value:
150016001[CR]
OK[CR]
Meaning:
The PS Display value is 15V and
16A. It is in CC mode.
Input Command:
PROM
<voltage0><current0>
<voltage1><current1>
<voltage2><current2>[CR]
Return value:
OK[CR]
Save Voltage and Current value
into 3 PS memory locations
<voltageX>=???
<currentX>=???
(X is memory location number
start from 0 to 2)
Input command:
PROM111111022122033133[CR]
Return value:
OK[CR]
Meaning:
Preset Memory 0 as 11.1V and
11.1A
Preset Memory 1 as 2.2V and
12.2A
Preset Memory 2 as 3.3V and
13.3A
Input Command:
GETM
[CR]
Return value:
<voltage0><current0>[CR]
<voltage1><current1>[CR]
<voltage2><current2>[CR]
OK[CR]
Get saved Voltage and Cur-
rent value from 3 PS memory
loctions
<voltageX>=???
<currentX>=???
(X is memory location number
start from 0 to 2)
Input command:
GETM
[CR]
Return value:
111111[CR]
122122[CR]
133133[CR]
OK[CR]
Meaning:
PS return following preset value
from 3 memory locations;
Memory 0 is 11.1V and 11.1A
Memory 1 is 12.2V and 12.2A
Memory 2 is 13.3V and 13.3A
Input Command:
RUNM
<memory>[CR]
Return value:
OK[CR]
Set Voltage and Current using
values saved in memory loca-
tions
<memory>=0/1/2
Input command:
RUNM1[CR]
Return value:
OK[CR]
Meaning:
Set Voltage and Current using
values saved in memory loca-
tion 1