19
MODELS
PSC-6916
PSC-6932
PSC-6960
Output
Variable Output Voltage
1 - 16VDC
1 - 32VDC
1 - 60VDC
Variable Output Current
0 - 60A
0 - 30A
0 - 15A
Voltage Regulation
Load (10-100% Load)
50mV
Line (108-132VAC Variation)
50mV
Current Regulation
Load (10-90% Rated Voltage)
200mA
150mA
100mA
Line (108-132VAC Variation)
50mA
Ripple & Noise
Ripple & Noise (r.m.s.) Voltage
5mV
Ripple & Noise (peak-peak)
Voltage
50mV
50mV
100mV
Current Ripple & Noise (r.m.s.)
100mA
40mA
15mA
Meter Type & Accuracy
Voltage Meter
3 Digit LED Display ±0.2% +3 counts
Current Meter
3 Digit LED Display ±0.2% +3 counts
Other
Input Voltage
120VAC / 60Hz
Full Load Input Current
9.6A
9.6A
9.5A
Efficiency
84.5%
87%
87.5%
Switching Frequency
65 - 85Khz~
75 - 95Khz~
65 - 85Khz~
Tracking Over Voltage Protec-
tions
O/P 1-5V: set v2V
O/P 5-15V: set v3V
O/P 1-5V: set v2V
O/P 5-20V: set v3V
O/P 20-30V: set v4V
O/P 1-5V: set v2V
O/P 5-20V: set v3V
O/P 20-60V: set v4V
Transient Response Time (50-
100%Load)
1.5ms
Power Factor Control
Power factor correction >0.95 at optimal load
Cooling Method
Thermostatic Control Fan from Zero to full speed
Protections
Overload, Short Circuit by Constant Current, Output Tracking Over
Voltage, Over Temperature
Fuse
T12A / 250V (5 x 20 mm)
Special Features
3 User defined VI preset, Remote control V, I and output on-off, Remote Sens-
ing (for PSC-6916 only)
Accessory
User Manual, Application Software, USB cable
Dimensions (WxHxD)
200 x 90 x 275 mm 7.9 x 3.5 x 10.8 inch
Weight
3.2 kg 7 lbs