2
4. From the assembly drawing or instruction manual (see Table 1, Pump Parts List) provide the IDP number(s) and
names for the replacement part(s).
5. Give the above information to your Imo service representative.
Imo sales and service representatives are listed herein and in General Instruction Manual, CA-1.
F. OPERATION
LIQUID LIMITATIONS
Never operate with fluids that are corrosive to iron, steel, aluminum or bronze. The pump is designed for fluids having the
general characteristics of oil.
CAUTION
ATTENTION
Operating conditions, such as speed, fluid viscosity, temperature, inlet pressure, discharge pressure,
filtration, duty cycle, drive type, mounting, etc. are interrelated. Due to these variable conditions, the
specific application limits may be different from that of the operational limitations. This equipment must
not be operated without verification that operating requirements are within its capabilities.
Single Pump Model Key:
CIG 33 016
R/L I/D P/W
Series
Frame Size
(2, 3, 4, 5, 6, 8)
*Pressure Rating
2 = Single Stage
3 = Two Stages
4 = 3 Stages
5 = 4 Stages
6 = 5 Stages
Nominal Displacement
In CM
3
/Rev.
Mechanical Seal Version
P – Standard Viscosity Fluids
W – Low Viscosity Fluids
I – Internal Drain (Standard)
D – External drain For High
Suction Pressure (Optional)
R – CW Rotation (Standard)
L – CCW Rotation
NOTE:
Mechanical shaft seals are available for all frame sizes except frame 2.
Figure 1 – Series Single Pump Configurations With Mechanical Seals
G. PUMP DISASSEMBLY
Refer to Assembly 1 for one stage (X1, X2) pumps
Refer to Assembly 2 for multistage (X3, X4, X5, X6) pumps
1. Remove drive key (36)
2. Remove capscrews (38) and end cover (15) with O-ring (35).
3. Remove capscrews (39) and washers (34) (Washers not used on single stage units).