Commissioning, Startup, Operation & Shutdown
216 Series Twin-Screw Pump -
Installation, Operation & Maintenance Manual
49
Lubricating-oil requirements (216.40 pumps only)
Oil quality requirements
Use a
high-grade synthetic gear oil
with
anti-foaming agents; oxidation and
corrosion inhibitors. It is suggested that the oils conform approximately to the
following characteristics.
Maximum pumped fluid temperature
100°C (212°F)
Bearing Alarm temperature
100°C (212°F)
Bearing Shutdown temperature
110°C (230°F)
ISO Synthetic Grade
VG100
Viscosity, kinematic @ 40
o
C (104°F)
95 - 105 cSt
Viscosity, kinematic @ 100
o
C (212°F) 13 cSt
Viscosity Index, Min
140
Flash point, Min
220 °C (428°F)
Acceptable lubricants
Replacement Oil must be the same as, or equivalent to the above.
Grease quality requirements
N/A
– Greased for Life is utilized for grease lubricated bearings
Lubricate the bearings with oil (216.40 pumps only)
WARNING:
Risk of explosive hazard and premature failure from sparks and heat generation. Ensure
That the bearings are properly lubricated prior to startup.
Remove the filler plug in the top of each housing. Refer to the GA or outline drawing for
location.
Fill each housing using a funnel.
Reinstall the filler plug and tighten.
Check that the oil level is correct. The correct oil level is at the center of the sight glass, when
the pump is stopped. During operation the sight glass gives a false oil level reading.
Lubricate the gear/bearings after a shutdown period (216.40 pumps only)
1. Fill each housing with the proper lubricating oil after cleaning.