Document: Service Manual
Description: Treadmill
Model: M7 E / M7L E
Page: 20 of 25
20
2.6.
Membrane key
Step
illustrate
Auxiliary Photo
1.
To pull out the connection from console
PCB.
2.
If mull-function when you are using, please
find the PINs definition for keys terminal as
below.
To measure the PINs by multi-meter then
press the mull-function key and keep on, it
shall be have low resistance in the normal
condition(short condition), if got infinity
resistance, the membrane key is damaged.
For example: SPEED UP key mull-function, to
measure the Pin 4 and Pin 8.
PIN
P1
P2
P3
P4
P5
P6
P7
P8
P9
P10
P1
INCLINE 9
SPEED 8
INCLINE
↑
P2
INCLINE 6
SPEED 6
SELECT
P3
INCLINE 3
SPEED 4
SPEED
↓
START
P4
INCLINE 0
SPEED 2
SPEED
↑
ENTER
P5
INCLINE12
SPEED 10
INCLINE
↓
P6
INCLINE 9
INCLINE 6
INCLINE 3
INCLINE 0
INCLINE12
P7
SPEED 8
SPEED 6
SPEED 4
SPEED 2
SPEED 10
P8
INCLINE
↑
SPEED
↓
SPEED
↑
INCLINE
↓
P9
SELECT
START
ENTER
P10
P1
P10
Summary of Contents for M-7 SERIES E TYPE