Document: Service Manual
Description: Treadmill
Model: M7 E / M7L E
Page: 13 of 25
13
2.1.3.2.
Check speed output device
Step
illustrate
Auxiliary Photo
1
Switch ON the AC power, short the enable
motor component by metalwork and keep
on.
Short the motor fast component by
metalwork, then metalwork leave the motor
fast component (open), to do 5~10 times
circulates.(short
open
short
open…)
Motor shall start to rotate and increase
speed, if you to do more circulate it will be
faster.
If to operate with console but shows LS, but
use this kind of way to operate the motor
and motor worked, it is mean that the
interface PCB is damaged.
Short the enable motor component (U5) by
metalwork
Short the motor fast component(U2) by
metalwork
Metalwork leave the motor fast component
(U2)
Motor shall start to rotate and increase
speed