FuzzySca
n
Pr
o
g
ram
mi
ng Ma
n
ua
l
Configuring Your Scanner
64
PROGRAM
Operation Control
Buzzer Tone & Volume Adjust,
Power On & Good Read Indicator Control
F_DEFAULT
Family Code Selection
P.C
Parameter Selection
Option Code
Buzzer Tone Adjust
SS
SS
SS
SS
SS
SS
SS
Buzzer tone – mute
Buzzer tone – low (Frequency 1.20 kHz)
Buzzer tone – medium(Frequency 2.70 kHz)◄
Buzzer tone – high (Frequency 2.81 kHz)
Buzzer tone - extremely high (Frequency 2.93 kHz)
Power-on beep◄
No power-on beep
0
1
2
3
4
5
6
Buzzer Volume
SS
SS
SS
Low
Medium
High◄
0
1
2
Power On Indicator
SS
SS
SS
Disable (LED off)
LED steady on◄
LED flash
0
1
2
Good Read Indicator
SS
SS
Disable
Enable◄
0
1