FuzzySca
n
Pr
o
g
ram
mi
ng Ma
n
ua
l
Configuring Your Scanner
77
PROGRAM
Condensed DataWizard
Data Organizer Setting
F_DEFAULT
Family Code Selection
P.C
Parameter Selection
Option Code
2nd Option Code
Organizer Control
SS
MS
MS
Disable◄
Select one barcode symbology
Select all barcode symbologies
FIN
(2 digits)
00
Automatic termination
Automatic termination
1st Organization
SS
DS
Disable◄
Enable
2-digits identified position;
Forward/backward data transmission setting
FIN
(2 digits)
position
direction
0 (Forward)◄
1 (Backward)
2nd Organization
SS
DS
Disable◄
Enable
2-digits identified position;
Forward/backward data transmission setting
FIN
(2 digits)
position
direction
0 (Forward)◄
1 (Backward)
Include/Exclude Control
SS
DS
Transmitted data excluded the data of identified position◄
Transmitted data included the data of identified position
0
1
The
Data Organizer
is used to edit the scanned raw data prior to transmitting the data to the host computers or terminals. It allows you to select desired barcode
symbologies for organizer control, and provides maximum two identified positions to send the data
forward
or
backward
. It also allows you to control the transmitted data
including
or
excluding
the data of identification position. Please refer to the application example listed in page 75 for details.
While the Data Organizer is enabled, it arranges only scanned data without
Preamble
,
Postamble
,
STX
,
ETX
,
Data Length
,
Prefix/Suffix Symbology ID
or
Record
Suffix
.
Regarding the “
Barcode Selection
” and “
Position Calculation
” of Data Organizer, please refer to page 75 for details.
Please note that all “
Character
” input should be referred to the
ASCII/HEX Table
.