36
OXE 125/150/175/200 HP INSTALLATION MANUAL
BLEEDING THE FUEL SYSTEM
NOTE!
In order for the diesel fuel system to work properly, the fuel lines must
be full of fuel and free from air. It is necessary to bleed/evacuate the air from the
system before operating the outboard.
Evacuating air from the fuel system
1.
Turn the ignition key
ON
. The fuel pump will run for 20 seconds.
NOTE!
Do not turn the ignition key to
START
. This could damage the fuel rail
pressure pump.
2.
Turn ignition
OFF
and wait 15 seconds. Repeat this cycle 3 times.
Air could enter the fuel system in any of the following ways:
-
The outboard has just been installed.
-
The engine ran out of fuel.
–
The fuel lines have been damaged and or leaking joints.
-
The fuel filter was removed for service or replacement.
-
The fuel lines were removed or disconnected for servicing.
-
The fuel lines are poorly connected.
-
The fuel pump was removed for servicing.
-
The fuel filter water drain cock was opened while the engine was running.
If one or more of the above occures, and air has entered the fuel system, you
will need to bleed/evacuate the air from the system as described above, prior to
operating the OXE outboard. Depending on the fuel system setup it may in some
cases be harder to bleed and you may need to follow a special procedure to bleed
the final air out which is described below.
!
WARNING
This is only allowed to be done once during the break-in procedure and
should be done with caution by authorized personnel only.
If the fault codes SPN102 and SPN173 appear on the display during the initial
seatrail you should perform the procedure below.
If fault codes
SPN102 Fmi 0
and
SPN173 Fmi 0
appear on the display proceed
as follows:
3.
Throttle down to Idle and stay there for approx. 1 minute.
4.
Turn the engine off and leave the engine off for approx 1 minute.
5.
Turn ignition on and make sure fault codes are not present.
6.
Start the engine and let it sit at idle for 1-2 minutes.
!
WARNING!
Operate in a safe manor at your own risk!
7.
Do a WOT run for 1-3 minutes at full load.
NOTE!
For fault code list, refer to
User Manual
.
FUEL SYSTEM
Summary of Contents for OXE Diesel 125 HP
Page 2: ......
Page 4: ...4 OXE 125 150 175 200 HP INSTALLATION MANUAL...
Page 8: ...8 OXE 125 150 175 200 HP INSTALLATION MANUAL...
Page 28: ...28 OXE 125 150 175 200 HP INSTALLATION MANUAL ELECTRO STEERING WITH JOYSTICK STEERING...
Page 64: ...64 OXE 125 150 175 200 HP INSTALLATION MANUAL...
Page 68: ...68 OXE 125 150 175 200 HP INSTALLATION MANUAL...
Page 74: ...74 OXE 125 150 175 200 HP INSTALLATION MANUAL...
Page 76: ...76 OXE 125 150 175 200 HP INSTALLATION MANUAL...
Page 78: ...78 OXE 125 150 175 200 HP INSTALLATION MANUAL...
Page 80: ...80 OXE 125 150 175 200 HP INSTALLATION MANUAL...
Page 82: ......
Page 83: ......