Furthermore, by opening the handle tap (P12) of the dust powder mixer,with manual distributor (P9)
or electrical distributor (E9) closed, it is possible to carry out the product mixing.
A different momentary positioning of the lever is required at times, but only for certain operations that
will be specified from time to time.
b. POWDERS’ MIXING (Horizontally, rightwards)
Only the mixing of powder products is to be carried out in this position
The pump delivery is sent to the filter (P7). By opening the faucet (P12) and closing the distributor (P9
or E9), the delivery is sent to the mixer (P13) of the main pipe union.
The flow to the tank is closed, through the regulator (P5) and (T2) and the delivery
towards the distribution device (sprayhead), therefore there is no delivery and
it is not possible to do the treatments. The hydraulic agitation is partially
maintained through the additional agitation pipeline (T9)
c. DETACHMENT/REATTACHMENT OF THE FILLING PIPE (Vertically, upwards)
The flows towards piping (T2) is interrupted.
This is to be positioned AT THE END of the tank’s filling operation, before
disconnecting the filling up piping. (TR) (accessory). NEVER OPERATE THE SPRAYER
WITH TAP (P6) IN THIS POSITION.
d. FILTER MAINTENANCE (Horizontally, leftwards)
The flow to piping (T2) is open. The capacity flow towards filter (P7) and to the feeding circuit is closed.
This allows the cleaning of filter (P7) even with a full tank; check that tap (P12) is closed.
P5. MANUAL PRESSURE REGULATOR
It is mounted on the tank and is connected to tap (P6) through piping T2. It regulates the operating
pressure by controlling the return flow to the tank.
—
By closing it: it REDUCES the return flow to the tank
and therefore, the agitation of the mixture,
00186
350
300
250
200
150
100
50
50 Pl
P5
and it increases the operating pressure and
capacity flow to the head (rotate the handle
clockwise).
—
By opening it: it INCREASES the return
flow to the tank
and therefore, the agitation
of the mixture, while reducing the operating
pressure and capacity flow to the head
(rotate the handle anti-clockwise).
09-2008
Plus 42 - 45 - 50 - 55
49
350
300
250
200
150
100
50
13
MAINTENANCE OPERATIONS
13
ALL OPERATIONS MUST BE CARRIED OUT WITH THE ENGINE SWITCHED OFF AND WITH
THE IGNITION KEY REMOVED FROM THE CONTROL PANEL.
13.1 - LUBRICATION
Carefully clean the greasing nipples and the oil filler in order to avoid that, during
lubrication, dirt might be introduced. In the case of intensive use of the machine,
reduce the lubrication intervals.
Maintenance point
Action
Consumption material
Periodicity
Fan shaft bearings support
Check oil level
Oil SAE 90
8 hours
Fan belt-tensioner support
Greasing
Grease Type EP Classe NLGI 2
200 hours
Free wheel
Greasing
Grease Type EP Classe NLGI 2
200 hours
Fan shaft bearings support
Change oil
Oil SAE 90
Annuary
UMAPT011
00065
00065
FAN
BELT-TENSIONER
SUPPORT
FREE WHEEL
00128
00130
00298
FAN SHAFT BEARINGS SUPPORT
OIL
MAX
MIN
8 h
CONTROLLARE
CHECK
CONTRÔLER
CONTROLAR
95079