3.5 Technical overview of device:

C.  Inlet connection (feed water)  

 for fl exible hose, with thread ¾“

E.  Outlet connection (softened water)  

 for fl exible hose, with thread ¾“

G1. Brine storage cabinet  

 salt fi lling

G2. Connection to brine  

 internal connection

O.   Overfl ow connection  

 for fl exible hose, threadless ½“

L.   Control valve  

 fl ow regulation

M.   Servo motor  

 for control valve

I.   Waste water connection  

 external drainage of waste water

Attention:

 Pipework sized min. DN50. Use only the fl exible hoses included in the delivery.

Ensure a correct sealing and setting of all pipes before fi rst commissioning.

Attention:

 To comply with good plumbing practice the external waste-water-drainage must have a mini-

mum space of air: 20 mm (according to guideline EN 14743).

Attention:

 Drainage from the overfl ow of the brine tank, Connections between the channel and two fl exible 

hoses (according to standard EN 3131).

Protection of device:

 To increase the lifetime of your softener ensure it is kept in a clean, dry place with an 

ambient temperature between 5 and 40 °C. Do not mention damage to resin or components.

I.

C.

E.

G1.

L.

 

O.

G2.

C.

M.

 

L.

 

E.

I.

 

3.6 Installing your softener

1. Positioning the water softener

It is very important to establish the water pressu-

re before installing the water softener. If the water 

pressure  is  low  then  the  water  softener  may  not 

operate  effectively.  If  it  is  too  high,  then  compo-

nents inside the unit may be damaged.

Water pressure should be tested with a gauge at 

the kitchen tap or outside tap. It should be noted 

that  water  pressure  can  increase  at  periods  of 

low water usage e.g. overnight.

 If therefore, the 

daytime pressure exceeds 5.0 bar UK, 8.0 bar 
EU or if you are unsure about pressure, then a 

pressure reducing valve should be fi tted.

 

Where the pressure is less than 

1.7 bar UK, 1.0 

bar EU

 a booster pump may be required.

2. Inlet and outlet connections

With  the  bypass  valve  open  and  the  inlet  /  outlet 

valves closed the unit can be connected to the plum-

bing system. Arrows on the inlet and outlet piping 

from the valve will confi rm the direction of fl ow.

Connections can be made with either conventional 

copper tube and fi ttings or the high fl ow fl exible ho-

ses supplied, ensure hoses are not kinked as this 

may restrict fl ow.

3. Drain connection

Push the fl exible drain hose onto the barbed con-

nector (Drain) as shown on 

page 7

 and secure with 

the clip provided. Run the drain hose to a stand 

pipe or to a drain. 

The air gap needs to be at least 

20 mm

. Softened water will have no adverse effect 

on a septic tank. You can extend the drain up to 9m 

if you have suffi cient pressure (greater than 

3 bar

). 

The drain hose must not be kinked or restricted in 

any way as this will cause an overfl ow from the bri-

ne cabinet.

Frost protection

If the drain hose or connecting pipework is likely 

to be subject to 

temperatures below 0°C it must 

be protected

 to prevent freezing. Failure to obser-

ve this precaution could lead to the water softener 

overfl owing.

Raising the drain hose

If you have a water pressure of 

3 bar 

or more, 

you 

can

 raise the drain to a maximum of 3 metres abo-

ve the valve head.

4. Overfl ow connections

The hose barb overfl ow pipe (not supplied with the 

softener) should be connected to the push fi t elbow 

at the rear of the cabinet (see page 9).

Run the pipe downhill to the drainage. Take care 

that the overfl ow does not discharge where dama-

ge could occur.

If the water softener is fi tted in a cellar or basement, 

the overfl ow can be run to a storage tank. Do not 

elevate the overfl ow hose.

Note:

 Do not use jointing cement on the fi tting.

5. Electrical connections

For added safety, peace of mind and ease of in-

stallation, your water softener is powered by low 

voltage via a plug in transformer. This transformer 

must be connected to a switched socket.

Attention:

 Plug the transformer into the socket

with the switch in the 

OFF-position

.

6. Filling the brine cabinet, salt- usage and alarm

Now place the water softener salt in the brine ca-

binet. Use the care cubes (tablet salt) or block salt 

(UK), from your local dealer.

Notes on salt usage:

 Your water softener will only 

perform effectively if there is salt in the brine cabi-

net during the regeneration process.

It is therefore essential that the salt level does not 

fall  lower  than  150mm  in  depth  when  measured 

from the base of the brine cabinet. 

N.B. The sof-

tener requires no priming, add no water to the 
brine tank.

 During regeneration, salt will not enter 

your water system as the salt used in the regenera-

tion process is rinsed safely away to drain.

Salt alarm is optional - not standard on most 
models.

  Depending  on  your  model  your  water 

softener may be equipped with a low salt alarm, 

this monitors your salt usage and sounds an audi-

ble alarm while displaying the low salt error code 

“SALt“

 when your salt levels falls to the minimum 

level. 

To reset the salt alarm fi ll the system with 

salt and press the SET-key.

7. Blending control

All  machines  are  fac-

tory  set  to  produce 

water  that  is  soft. 

Note: If you prefer wa-

ter which is less soft, 

turn the blending knob 

on the left side of the 

valve  anti-clockwise 

until the water meets your requirements.

8. Testing for the water hardness in your area

Water hardness can vary from one location to

another. To determine the hardness of the water

feeding your water softener (unsoftened supply)

use the hardness test kit supplied. 

•  Fill the test bottle supplied to the fi ll line with

  water from a hard water tap.

OPM - Cillit Access 10-25 vOrange - EN, DEv4.indd   12-13

02/10/2012   09:48

Summary of Contents for Access 10

Page 1: ...bau und Bedie nungsanleitung stets griffbereit aufzubewahren vor der Ausf hrung von Ar beiten am Ger t vollst ndig durchzulesen und zu beachten Unsere Merk bl tter und Druckschriften sollen nach beste...

Page 2: ...the hardness of blended water 16 5 Maintenance 16 5 1 Maintenance work 16 5 2 Operator responsibilities 16 5 3 Maintenance wearing parts 16 5 4 Disposal 16 6 Fault finding 17 6 1 Trouble shooting Guid...

Page 3: ...pplication Cillit Access is desig ned for softening or partially softening domestic water in accordance with the relevant regulati ons All other use is strictly forbidden and your own responsibility 1...

Page 4: ...ally dependent on the hard ness of the supply and amount of water used The default time of day when this is to occur is 2 00am To alter this setting use the UP DOWN keys Pressing the SET key once ente...

Page 5: ...ion protection Attention Water pressure must never exceed the unit s maximum of 5 0 bar UK 8 0 bar EU If the network water pressure is higher than 4 0 bar UK 6 0 bar EU or you are unsure about pressur...

Page 6: ...ater softener In case of low sodium diet follow the local department of health s advice concerning the use of softened water for drinking Note Water that is used for mixing powdered milk for babies mu...

Page 7: ...d or restricted in any way as this will cause an overflow from the bri ne cabinet Frost protection If the drain hose or connecting pipework is likely to be subject to temperatures below 0 C it must be...

Page 8: ...l operation there is a char ge bar running along the bottom of the display This charge bar shows the percentage of water softener capacity remaining since the last regeneration Im mediately following...

Page 9: ...aced within the prescribed maintenance intervals in order to guarantee functionality and fulfil the warranty conditions The water softener should be serviced once a year Wearing parts may only be repl...

Page 10: ...e home position is not detected within 10 minutes the main display will show an Err 1 message to indicate a controller error and an audible alarm will sound The error condition can only be cleared by...

Page 11: ...ox kg 65 Tested with HiFlow connection available in option 7 2 Cillit Access 15 15 Bio Cillit Access Unit 15 15 Bio Nominal connection outside thread BSP DN 20 Nominal flow rate in accordance with EN...

Page 12: ...The company BWT UK Ltd declares that the product domestic water softener with the following specifications Trade name of product Type of product Model Cillit Access 10 10 BIO 10 litres Cillit Access...

Page 13: ...37 4 3 H rtegrad des Mischwassers festsetzen 38 5 Wartung 38 5 1 Wartungsarbeiten 38 5 2 Betreiberverantwortung 39 5 3 Wartungs Verschlei teile 39 5 4 Entsorgung 39 6 Betriebsst rungen 40 6 1 Leitfad...

Page 14: ...deckung abgenom men wurde Beachten Sie Benutzen Sie bei Bedarf Schutzkleidung Beachten Sie Zus tzliche Information f r die Bedie nungsperson 1 4 Bestimmungsgem e Verwendung Die Weichwasseranlage ist d...

Page 15: ...egelm igen Abst nden rege nerieren abh ngig von der H rte und der Menge des zugef hrten Wassers Die Standardzeiteinstel lung daf r ist 2 Uhr Fr h Um diese Einstellung zu ver ndern benutzen Sie die UP...

Page 16: ...wankungen durch benachbarte elektrische Systeme darf den Ma ximalwert wie er in EN 61000 6 3 spezifiziert ist nicht berschreiten Datenanlyse des Rohwassers in Ihrer Gegend Ein Dauerbetrieb des Wassere...

Page 17: ...F rderh hen systeme Der Wasserenth rter kann nach Bedarf mit einem Hochvolumenf rderstrom Satz und flexiblen Hochvolumenf rderstromschl uchen passend f r 22mm Leitungen geliefert werden f r 15mm Leitu...

Page 18: ...laufschlauch zu einem Standrohr oder Ablauf Der Luftspalt muss mindestens 20 mm betragen Weichwas ser hat keine potenziellen Schadwirkungen auf eine Kl rgrube Sie k nnen den Abfluss auf bis zu 9m verg...

Page 19: ...das die Solemenge an den Bedarf f r eine Teilregeneration anpasst Der Konsum des Rege nerierungsmittels und Wassers wird auf das Mini mum reduziert Im Fall eines Stromausfalls werden Daten und Ze ten...

Page 20: ...schneideventils V dem gew nschten Wert an H rte in ppm Anzahl der Personen 02 03 04 05 06 150 8 7 6 5 4 200 7 6 5 4 3 250 6 5 4 3 2 300 5 4 3 2 1 350 4 3 2 1 1 400 3 2 1 1 1 Anzahl der Tage zwischen...

Page 21: ...ten Sie einen Regenerationszyklus indem Sie den manuellen Regenerationsknopf RECHARGE dr cken und l nger als 6 Sekunden gedr ckt halten Achtung Funktioniert Ihr Wasserenth rtungsger t nicht so wie es...

Page 22: ...ca kg 40 Gepr ft mit Hochdurchfluss Verbinder optional erh ltlich 7 2 Cillit Access 15 15 Bio Cillit Access Typ 15 15 Bio Durchflussleistung Au engewinde BSP DN 20 Nenndurchfluss nach EN 14743 l h 156...

Page 23: ...Gepr ft mit Hochdurchfluss Verbinder optional erh ltlich 7 4 Cillit Access 25 25 Bio Cillit Access Typ 25 25 Bio Durchflussleistung Au engewinde BSP DN 20 Nenndurchfluss nach EN 14743 l h 1680 Betrie...

Page 24: ...nien Leitf den konstruiert produziert und endgefertigt wurde 2006 95 EG Richtlinie f r Niederspannung NSR 2004 108 EG Richtlinie f r elektromagnetische Vertr glichkeit EMV Beachten Sie F hren Sie ohne...

Page 25: ...9 02 201058 E Mail cillichemie cibemi it Cilit S A E 08940 Cornell de Llobregat Barcelona P I del Este Silici 71 73 Tel 34 93 4740494 Fax 34 93 4744730 E Mail cilit cilit com Cillit Direction Commerci...

Reviews: