background image

4

5

EN

EN

1. Introduction

1.1 General comments

Please  read  this  manual  carefully  and  famliari-

se yourself with the operating instructions before 

using this equipment.

Models covered by this manual:

Cillit

®

 Access for the device types:

•  10 / 10 Bio

•  15 / 15 Bio

•  20 / 20 Bio

•  25 / 25 Bio

The local standards as well as technical specifi ca-

tions have to be observed.

The  operating  instructions  must  be  read  in 

conjunction  with  any  national  regulations  con-

cerning  accident  prevention  and  environmental 

protection.

Prior to putting the device into operation, read the 

operating instructions completely and thoroughly.

Please keep this manual close to hand for quick 

reference to the unit’s operation.

The device shall only be used for its intended pur-

pose,  in  line  with  the  operating  instructions  and 

only in the environment to which intended.

Note: Never exceed the defi ned maintenance and 

service intervals.

1.2 Manufacturer

BWT UK Ltd.

Coronation Road, BWT House

High Wycombe

Buckinghamshire, HP12, 3SU

Phone:   +44 / 1494 / 838 100

Fax:  

+44 / 1494 / 838 101

E-mail:   [email protected]

1.3 Safety instructions

Danger 

caused by electric current or  

voltage!

Always consult a qualifi ed electrician

when working on places denoted by this 

symbol.

The complete power supply unit must be replaced

in the event of damage to the mains cable.

Warning:

Do not use any aggressive cleaning

agents!

If a power failure occurs when regeneration waste

water and overfl ow are being drained into a

sump, fl ooding may occur.

Please observe:

Use only trained or instructed staff.

Stipulate clear staff responsibilities

for operation, set-up, maintenance

and repair work.

Please observe:

NEVER operate the device with the

housing covers removed.

Note:

If needed use protective clothing.

Note:

Additional information for the

operator.

1.4 Intended use

The domestic application Cillit

®

 Access is desig-

ned  for  softening  or  partially  softening  domestic 

water  (in  accordance  with  the  relevant  regulati-

ons.) All other use is strictly forbidden and your 

own responsibility.

1

14

15

4

5

2

12

8

13

18

11

10

1.5 Scope of delivery

Cillit

®

 Access water softer with:

Standard delivery:

1.  Multi-way control valve with

 

microprocessor controller

2.  Blending valve

3.  Softening column with ion exchange resin

4.  Softened water outlet

5.  Hard water inlet

6.  Drain water

7.  Overfl ow connection

8.  Mains plug power supply connection

9.  Operating manual

10. Hose clamp connection

11.  2 m drain water hose

12. Cover with short user instructions

13. AQUATEST hardness tester

Please open the cover (12), (See page 9):

14. Salt storage

15. Cabinet

16. Fixing material (See page 9)

17. Rating plate and

 

serial number (See page 9)

Additional delivery:

18. Non-return valve BSP: ¾” (DN: 20/20)

 

Important notice: 

Always keep the fitting and operating instructions close 

at  hand  to  avoid  any  mistakes  and  before  carrying  out  any  work  on  the 

device you should read the fitting and operating instructions carefully and 

follow them. While our data sheets and brochures should provide advice to 

the best of our knowledge, the content thereof is not legally binding. 
Changes of technical details are reserved!

Wichtige Hinweise: 

Um Fehler zu vermeiden, ist die Einbau- und Bedie-

nungsanleitung stets griffbereit aufzubewahren, vor der Ausführung von Ar-

beiten am Gerät vollständig durchzulesen und zu beachten. Unsere Merk-

blätter und Druckschriften sollen nach bestem Wissen beraten, der Inhalt ist 

jedoch ohne Rechtsverbindlichkeit. Im Übrigen gelten unsere allgemeinen 

Geschäftsbedingungen.
Änderungen bei technischen Details sind vorbehalten!

Cillit-GD 03-10001 / Rev. 1.02 – EN, DE / CIL10-25 / 2011-11 

 

BWT UK Ltd. 

Cillit

®

 Access

Domestic water softener
10, 15, 20, 25

Weichwasseranlage
10, 15, 20, 25

Fitting and operating 
instructions 

EN

Einbau- und 
Bedienungsanleitung 

DE

9

12

6

7

3

OPM - Cillit Access 10-25 vOrange - EN, DEv4.indd   4-5

02/10/2012   09:48

Summary of Contents for Access 10

Page 1: ...bau und Bedie nungsanleitung stets griffbereit aufzubewahren vor der Ausf hrung von Ar beiten am Ger t vollst ndig durchzulesen und zu beachten Unsere Merk bl tter und Druckschriften sollen nach beste...

Page 2: ...the hardness of blended water 16 5 Maintenance 16 5 1 Maintenance work 16 5 2 Operator responsibilities 16 5 3 Maintenance wearing parts 16 5 4 Disposal 16 6 Fault finding 17 6 1 Trouble shooting Guid...

Page 3: ...pplication Cillit Access is desig ned for softening or partially softening domestic water in accordance with the relevant regulati ons All other use is strictly forbidden and your own responsibility 1...

Page 4: ...ally dependent on the hard ness of the supply and amount of water used The default time of day when this is to occur is 2 00am To alter this setting use the UP DOWN keys Pressing the SET key once ente...

Page 5: ...ion protection Attention Water pressure must never exceed the unit s maximum of 5 0 bar UK 8 0 bar EU If the network water pressure is higher than 4 0 bar UK 6 0 bar EU or you are unsure about pressur...

Page 6: ...ater softener In case of low sodium diet follow the local department of health s advice concerning the use of softened water for drinking Note Water that is used for mixing powdered milk for babies mu...

Page 7: ...d or restricted in any way as this will cause an overflow from the bri ne cabinet Frost protection If the drain hose or connecting pipework is likely to be subject to temperatures below 0 C it must be...

Page 8: ...l operation there is a char ge bar running along the bottom of the display This charge bar shows the percentage of water softener capacity remaining since the last regeneration Im mediately following...

Page 9: ...aced within the prescribed maintenance intervals in order to guarantee functionality and fulfil the warranty conditions The water softener should be serviced once a year Wearing parts may only be repl...

Page 10: ...e home position is not detected within 10 minutes the main display will show an Err 1 message to indicate a controller error and an audible alarm will sound The error condition can only be cleared by...

Page 11: ...ox kg 65 Tested with HiFlow connection available in option 7 2 Cillit Access 15 15 Bio Cillit Access Unit 15 15 Bio Nominal connection outside thread BSP DN 20 Nominal flow rate in accordance with EN...

Page 12: ...The company BWT UK Ltd declares that the product domestic water softener with the following specifications Trade name of product Type of product Model Cillit Access 10 10 BIO 10 litres Cillit Access...

Page 13: ...37 4 3 H rtegrad des Mischwassers festsetzen 38 5 Wartung 38 5 1 Wartungsarbeiten 38 5 2 Betreiberverantwortung 39 5 3 Wartungs Verschlei teile 39 5 4 Entsorgung 39 6 Betriebsst rungen 40 6 1 Leitfad...

Page 14: ...deckung abgenom men wurde Beachten Sie Benutzen Sie bei Bedarf Schutzkleidung Beachten Sie Zus tzliche Information f r die Bedie nungsperson 1 4 Bestimmungsgem e Verwendung Die Weichwasseranlage ist d...

Page 15: ...egelm igen Abst nden rege nerieren abh ngig von der H rte und der Menge des zugef hrten Wassers Die Standardzeiteinstel lung daf r ist 2 Uhr Fr h Um diese Einstellung zu ver ndern benutzen Sie die UP...

Page 16: ...wankungen durch benachbarte elektrische Systeme darf den Ma ximalwert wie er in EN 61000 6 3 spezifiziert ist nicht berschreiten Datenanlyse des Rohwassers in Ihrer Gegend Ein Dauerbetrieb des Wassere...

Page 17: ...F rderh hen systeme Der Wasserenth rter kann nach Bedarf mit einem Hochvolumenf rderstrom Satz und flexiblen Hochvolumenf rderstromschl uchen passend f r 22mm Leitungen geliefert werden f r 15mm Leitu...

Page 18: ...laufschlauch zu einem Standrohr oder Ablauf Der Luftspalt muss mindestens 20 mm betragen Weichwas ser hat keine potenziellen Schadwirkungen auf eine Kl rgrube Sie k nnen den Abfluss auf bis zu 9m verg...

Page 19: ...das die Solemenge an den Bedarf f r eine Teilregeneration anpasst Der Konsum des Rege nerierungsmittels und Wassers wird auf das Mini mum reduziert Im Fall eines Stromausfalls werden Daten und Ze ten...

Page 20: ...schneideventils V dem gew nschten Wert an H rte in ppm Anzahl der Personen 02 03 04 05 06 150 8 7 6 5 4 200 7 6 5 4 3 250 6 5 4 3 2 300 5 4 3 2 1 350 4 3 2 1 1 400 3 2 1 1 1 Anzahl der Tage zwischen...

Page 21: ...ten Sie einen Regenerationszyklus indem Sie den manuellen Regenerationsknopf RECHARGE dr cken und l nger als 6 Sekunden gedr ckt halten Achtung Funktioniert Ihr Wasserenth rtungsger t nicht so wie es...

Page 22: ...ca kg 40 Gepr ft mit Hochdurchfluss Verbinder optional erh ltlich 7 2 Cillit Access 15 15 Bio Cillit Access Typ 15 15 Bio Durchflussleistung Au engewinde BSP DN 20 Nenndurchfluss nach EN 14743 l h 156...

Page 23: ...Gepr ft mit Hochdurchfluss Verbinder optional erh ltlich 7 4 Cillit Access 25 25 Bio Cillit Access Typ 25 25 Bio Durchflussleistung Au engewinde BSP DN 20 Nenndurchfluss nach EN 14743 l h 1680 Betrie...

Page 24: ...nien Leitf den konstruiert produziert und endgefertigt wurde 2006 95 EG Richtlinie f r Niederspannung NSR 2004 108 EG Richtlinie f r elektromagnetische Vertr glichkeit EMV Beachten Sie F hren Sie ohne...

Page 25: ...9 02 201058 E Mail cillichemie cibemi it Cilit S A E 08940 Cornell de Llobregat Barcelona P I del Este Silici 71 73 Tel 34 93 4740494 Fax 34 93 4744730 E Mail cilit cilit com Cillit Direction Commerci...

Reviews: