2-5
Manual No 0-5072
INTRODUCTION welDskIll 250, 350
December , 2008
2.08 WeldSkill 250 MIG Power Source Specifications
Identification, Weights & Measures
WeldSkill 250
Plant Assembly
W003400
Plant Dimensions
(including cylinder carrier & wheels)
H 980mm x W 440mm x D 988mm
Power Source Part Number
W00340
Power Source Mass
00 kg
Energy Input (Refer NOTE Below)
This Column Applies to the
Factory Fitted 2.5mm
2
(20A)
Primary Lead
This Column Applies to a
4.0mm
2
(25A) Primary Lead
Input Cable Requirements
2.5mm
2
2 core + earth heavy
duty R90 insulation type.
4.0mm
2
2 core + earth heavy
duty R90 insulation type
Supply Input Voltage
240 VAC
240 VAC
Number of Phases & Frequency
Single Phase 50 Hz
Single Phase 50 Hz
Rated Input Current @ 00% Duty Cycle
♥
9.5 A
♥
27 A
Rated kVA @ 00% Duty Cycle
4.7 kVA
6.5 kVA
Maximum Input Current
43 A
54 A
Generator Requirements
♣
5 kVA
♣
5 kVA
Supply VA @ no load
480 VA
480 VA
Supply VA @ max. output
0.3 kVA
3 kVA
Rated Outlet Maximum Duty Cycle
20 A
30 A
Recommended Fuse Size
♠
45 A
♠
60 A
Welding Output (Refer NOTE Below)
This Column Applies to the
Factory Fitted 2.5mm
2
(20A)
Primary Lead
This Column Applies to a
4.0mm
2
(27A) Primary Lead
Open Circuit Voltage Range
22 to 46 V
22 to 46 V
Output Current Range
50 – 230 A
50 – 270 A
Rated Output Duty Cycle
230 A@ 20%
250 A@ 20%
00% Duty Cycle Output Rating
07 A
30 A
Operating Temperature Range
0ºC - 40ºC
0ºC - 40ºC
Duty Cycle Period
0 minutes
0 minutes
Number of Output Voltage Switch Settings
2
Maximum Inlet Gas Pressure
.2 MPa (gas hose)
Suitable Gas Types
Argon based mixed gases & C0
2
Wire Size Range Hard Wire:
Fluxcored Wire:
0.6mm – .0mm
.0mm – .2mm
Table 2- WeldSkill 250 Power Source Specifications
♥
The Rated Input Current should be used for the determination of cable size & supply requirements.
♠
Motor start fuses or thermal circuit breakers are recommended for this application. Check local
requirements for your situation in this regard.
♣
Generator Requirements at the Maximum Output Duty Cycle.
♦
Reduced output ratings apply with the supplied 20A primary lead. To achieve the maximum rated
output & duty cycle ratings the 20A primary lead must be replaced with a larger primary lead as
specified in section 3.04. This must be carried out be a qualified electrical tradesperson.
Summary of Contents for WeldSkill 250 MIG
Page 6: ......
Page 12: ...1 December 1 2008 weldskill 250 350 Manual No 0 5072 This page left intentionally blank...
Page 20: ...2 Manual No 0 5072 weldskill 250 350 December 1 2008 This page left intentionally blank...
Page 24: ...3 Manual No 0 5072 weldskill 250 350 December 1 2008 This page left intentionally blank...
Page 28: ...4 Manual No 0 5072 December 1 2008 weldskill 250 350 This page left intentionally blank...
Page 36: ...6 Manual No 0 5072 weldskill 250 350 December 1 2008 This page left intentionally blank...
Page 44: ...8 Manual No 0 5072 weldskill 250 350 December 1 2008 This page left intentionally blank...
Page 50: ......