Parameter
Description
DOWN SLOPE
This parameter operates in TIG modes only and is used to set the time for the weld
current to ramp down, after the torch trigger switch has been pressed, to
CRATER
CUR.
This control is used to eliminate the crater that can form at the completion of a
weld.
CRATER CUR.
This parameter operates in
SLOPE
or
REPEAT
(4T) TIG modes only and is used to
set the finish current for TIG. The CRATER Current remains on until the torch trigger
switch is released after it has been depressed.
POST-FLOW
This parameter operates in TIG modes only and is used to adjust the post gas flow
time once the arc has extinguished. This control is used to dramatically reduce
oxidation of the tungsten electrode.
The SAVE/LOAD buttons are used to save and retrieve a total number of 5 programs
into the 200 Pi memory. NOTE: SAVE/LOAD button must remain depressed for 3
seconds in order to save or load the settings.
Table 4-3 (continued): Parameter Descriptions
4.04 Weld Parameters for Transtig 200 Pi
Weld
Parameter
Parameter
Range
Factory
Setting
Incremental
Unit
STICK
HF
TIG
LIFT
TIG
PRE-FLOW
0.0 to 1.0 sec
0.1 sec
0.1 sec
No
Yes Yes
HOT START
0 to 70A
20A
1A
Yes Yes
No
INITIAL CUR.
1 to 200A
30A
1A
No
Yes Yes
UP SLOPE
0 to 15 sec
1 sec
0.1 sec
No
Yes Yes
PEAK CUR.
1 to 200A
120A
1A
No
Yes Yes
WELD CUR
1 to 200A 230V
80A
1A
No
Yes Yes
(TIG)
1 to 85A 115V
80A
1A
No
Yes Yes
WELD CUR
1 to 160A 230V
80A
1A
Yes
No
No
(STICK)
1 to 85A 115V
80A
1A
Yes
No
No
SPOT TIME
0.5 to 5.0 sec
2 sec
0.1 sec
No
Yes Yes
PULSE WIDTH
15 to 80%
50%
1%
No
Yes Yes
PULSE FREQ.
0.5 to 500Hz
100.0Hz See Table 4-5 No
Yes Yes
DOWN SLOPE
0 to 25 sec
3 sec
0.1 sec
No
Yes Yes
CRATER CUR.
1 to 200A
30A
1A
No
Yes Yes
POST-FLOW
0.0 to 60 sec
10 sec
0.1 sec
No
Yes Yes
Weld Mode
Table 4-4: Weld Parameters for Transtig 200 Pi
PULSE FREQ. Range
Incremental Unit
0.5 to 20Hz
0.1Hz
20 to 100Hz
1Hz
100 to 500Hz
5Hz
Table 4-5: PULSE FREQ. Range and Incremental Units