background image

12

RESOLUÇÃO DE PROBLEMAS

TROUBLESHOOTING

PROBLEM

INDICATOR

CAUSE

SOLU

TIONS

No water coming out 
of the Faucet:

1.Sensor flashes continu-
ously when user’s hands
are within the sensor’s
range.

Low battery.

Replace battery.

2. Red light in the sensor
does not flash (once) when
user’s hands are within the
sensor range.

1. Range is too short.
2. Range is too long.
3. Battery is completely used up
4. Unit is in “Security Mode” *
5. Sensor is picking up reflections from

the washbasin or another

object..

Increase the range.
Decrease the range.
The battery must be replaced.

Eliminate cause of reflection.

3. Red light in the sensor
flashes once when user’s
hands are within the sen-
sor range.

1. Connectors between the electronic
unit and solenoid are disconnected.
2. Debris or scale in solenoid.

3. The central orifice in the diaphragm is
plugged or the diaphragm is torn.
4. The water supply pressure is higher
than 8 bar.

Connect the electronic unit connectors to the solenoid.

Unscrew solenoid, pull out the plunger and the spring 
from the solenoid and clean them. Use scale remover 
material if needed. When replacing the plunger, 
please make sure that the spring is in vertical position.

Clean the orifice or replace diaphragm.
Reduce the supply water pressure.

Water flow from spout 
does not stop:

1. Sensor flashes once
when user’s hands are
within the sensor’s range.

2. Red light in the sensor
does not flash (once) when
user’s hands are within the
sensor’s range.

Debris or scale in diaphragm.

1. Sensor is dirty or covered.
2. Sensor is picking up reflections from
the washbasin or another object.

Clean the orifice or replace diaphragm.

Clean or eliminate case of interference.
Decrease the range or eliminate cause of reflection.

Water flow diminished:

Filter or aerator is clogged.

Remove, clean, re-install.

* “Security Mode”: If the sensor is covered for more than 90 sec. the faucet will automatically shut off water flow. To return to

normal operation remove any blockage to re-establish operation.

Summary of Contents for 3215001

Page 1: ...TORNEIRA ELETR NICA DE PAREDE 3215001 WALL MOUNTED ELECTRONIC FAUCET 3215001 MANUAL DE MONTAGEM E INSTRU ES ASSEMBLEY AND INSTRUCTIONS MANUAL...

Page 2: ...DO PACK PACK CONTENTS INFORMA O DE PR INSTALA O PRE INSTALLATION INFO INSTALA O INSTALLATION AJUSTE CONFIGURA ES RANGE ADJUSTMENT SUBSTITUI O DE BATERIA BATTERY REPLACEMENT MANUTEN O MAINTENANCE LIST...

Page 3: ...ing valve Self adjusting sensor 80 mm 240 mm 90 seconds 70 C TORNEIRA ELETR NICA DE PAREDE 3215001 WALL MOUNTED ELETRONIC TAP 3215001 Fonte de alimenta o Press o min de gua Press o max de gua Alcance...

Page 4: ...tr nica Spout and attachments incl electronic unit Perno M4x4 M4x4 set screw Capa protetora tempor ria Temporary protection cover 2x Parafuso 6x1 1 2 2x Srew 6x1 1 2 2x Buchas 5x25 2x Screw anchors 5x...

Page 5: ...o do sensor da torneira use um escoador com um acabamento n o refletivo n o use o acabamento cromado N o instale um escoador brilhante na dire o do sensor 1 To avoid reflection problems keep a distanc...

Page 6: ...he adjustable tilting plate by pressing it smoothly If the sensor range is not satisfactory please refer to the section entitled Settings adjustment INSTALA O INSTALLATION 1 Feche o fornecimento de gu...

Page 7: ...d distance 9 Check the distance you have set and if it is not satisfactory repeat steps 1 7 10 Turn on the water supply Regula o do alcance 1 Feche o fornecimento de gua 2 Desligue a fonte de alimenta...

Page 8: ...mpre que as m os do utilizador se aproximem do alcance do sensor A pilha 9V deve ser substitu da dentro de duas sema nas do seguinte modo 1 Corte o fornecimento de gua 2 Para ter acesso a pilha 9V des...

Page 9: ...rew this screw using the provided 4mm Allen key e Pull out the nipples and dismount the filters f Wash the filters under running water If needed replace the filters with new ones g Restore the filters...

Page 10: ...10 LISTA DE PE AS SPARTE PARTS LIST Kit Sensor Sensor Kit V lvula solen ide Solenoid valve Tampa das pilhas Battery cover Filtro Filter 07220082 07500065 06500001 08530014...

Page 11: ...ma dos 8 bar Ligar os conetores entre a unidade eletr nica e a solen ide Desaparafuse a solen ide extraia o pist o e a mola da solen ide e limpe os Use um removedor de cal c rio se necess rio Quando s...

Page 12: ...gher than 8 bar Connect the electronic unit connectors to the solenoid Unscrew solenoid pull out the plunger and the spring from the solenoid and clean them Use scale remover material if needed When r...

Page 13: ...IAL cobrar igualmente o valor da desloca o e da m o de obra realizada 3 1 VALORES A COBRAR Desloca o 0 40 km a contar a partir da localiza o do revendedor CIFIAL M o de obra 25 00 hora m nimo a cobrar...

Page 14: ...5665966 983XX884D 01 www cifial eu...