background image

 

 

assembly Instructions 

 

 For the models: 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LinJa GmbH & Co. KG 
Unterdürrbacherstr. 222 
97080 Würzburg 
Tel: +49 931 453 24 350 
Email: [email protected] 

 

Kopenhagen / EN2 

 

Larvik / E2 

 

Lillehammer / EA2 

 

 

Brevik / EN3 

 

Verdal / E3 

 

Oulu / EA3 

 

Molde / EN4 

 

Ruka / EA4 

Summary of Contents for Brevik

Page 1: ...tructions For the models LinJa GmbH Co KG Unterdürrbacherstr 222 97080 Würzburg Tel 49 931 453 24 350 Email info linja24 de Kopenhagen EN2 Larvik E2 Lillehammer EA2 Brevik EN3 Verdal E3 Oulu EA3 Molde EN4 Ruka EA4 ...

Page 2: ... Back and Sidewalls 5 Step 3 Bench 5 Step Front 5 Step 5 Roof 6 Step 6 Lamps 6 Step 7 Sauna Stove 6 Transport 6 Assembly Controller 7 Manual Controller 9 DO T 11 Installation 11 Function 11 Connecting the cables tot he control box 13 Connecting the Sauna Controller Display 14 Connecting the temperature sensor 15 Connecting the sauna stove 15 ...

Page 3: ...st be reported to us immediately with photos Please send these to reklamationen linja24 de Two people or three depending on the size of the cabin should set up the sauna taking these assembly instructions into account The power connection for the sauna must be carried out by a certified electrician He must also ensure sufficient grounding to avoid accidents and malfunctions Please have an electric...

Page 4: ...esia o obesity o diabetes o high blood pressure o Heart circulatory problems Usage tips recommended temperature 60 75 C The temperature displayed on the controller may differ from the temperature on the thermometer Drink enough water Shower before use Do not go to the sauna immediately after eating or strenuous activities e g sport Scope of delivery Count Element 1 Floor element 1 Ceiling element ...

Page 5: ...nel Please align the buckles and then tighten them Step 3 Bench Depending on the model please install the front bench panel for one or two benches To do this slide it along the horizontal guide on the side panels Be careful not to scratch the side panels Then please install the seat by mounting it on the bench panel Step Front Now please mount the front panel by placing it on the grooves of the bo...

Page 6: ...ect the lights for your sauna please pull the cables through the small holes in the roof panel The further cabling as well as the power connection takes place directly on the roof panel Step 7 Sauna Stove Please pull the cable of the sauna heater from the inside to the outside through the small hole in the side wall Although it is a 220 230V power supply we recommend having the connection done by ...

Page 7: ...applying pressure to the clip on the top Remove the 2 temperature sensor wires black jacketed and 5 connectors white jacketed 7 wires total from the controller Warning Be careful not to remove the flat white cable from the display Instead of the display the wooden bracket is built into the sauna wall To do this first pull all cables through the opening in the back of the holder ...

Page 8: ...ake sure the holes in the bracket are facing up to allow warm air to escape upwards Reattach the display surface Then screw the holder into the sauna wall in place of the controller s old position Make sure the holes in the bracket are facing up to allow warm air to escape upwards ...

Page 9: ...tch to the setting for the duration of the sauna session The time display starts flashing and can be set Press the button again to exit settings Alternatively the last step happens automatically after 15 seconds If the temperature in the sauna is higher than the set temperature the LED lights up red and the heater switches off If the temperature drops to 2 C below the set temperature the oven swit...

Page 10: ......

Page 11: ...e steam generator off again LIGHT Turns the lights on or off in the steam room When the lights are on the LIGHT indicator lamp will be lit TEMP Opens the temperature setting The temperature can be set between 35 C and 55 C by pressing the arrow keys TIME TEMP ON OFF LIGHT 1700 mm Power Control Sensor Work indicator up and down key Lighting indicator Temperature display TIME TEMP ON OFF LIGHT ...

Page 12: ...5XTAB Sauna heaters 3 4 5 2 5 13 8 6 20 8 6 23 4 5 Sauna heaters L3 L2 L1 N N 1 N W V U N 3XTAB Sauna heaters 6 16 40 6 16 45 8 10 26 8 10 30 230 240V 200 208V AWG mm2 2 Amp AWG mm Amp 9 6 KW TAB Sensor Control Relay box Sauna 4 5 9KW 200 240V 200 240V L3 Sensor 6 5 4 3 2 1 7 8 1 2 3 4 5 6 L1 L2 N Use 90 C copper wire 3XTAB Relay box Relay box Circuit board Control 6X0 2mm2 N L2 L1 L3 380V 3 N U V...

Page 13: ...s from the control display temperature sensor and sauna heater must be connected to the silver control box on the roof of the sauna This should only be carried out by a specialist The necessary cables are on the side of the cables where the control box is located taped to a side panel ...

Page 14: ...he control box on the roof by unscrewing it The white wire must be connected to the green circuit board Pull the cable through the hole on the far left Attach the connectors to the circuit board as follows Left to right Black Brown Red Yellow Green ...

Page 15: ... attach it to the ceiling with the bracket Connecting the sauna stove The sauna stove must also be connected to the control box on the roof 3 core cables are used for 3kw 4 5kw or 6kw ovens Pull the wire through the right hand opening in the control box and connect both the ground and all wires as shown in the picture ...

Reviews: