AQUACIAT
POWER™
ILD
1750R 2000R 2300R 2500R 2800R 3000R 3200R 3500R 4000R
Sound levels
Unit + High temperature option/Nominal high performance
Sound power
(1)
dB(A)
94,5
95,0
96,0
96,5
97,0
97,0
97,5
97,5
98,0
Sound pressure at 10 m
(2)
dB(A)
62,0
62,5
64,0
64,0
64,5
65,0
65,0
65,0
65,0
Standard unit
Sound power
(1)
dB(A)
92,5
93,0
93,5
94,0
94,5
94,5
95,0
95,5
96,0
Sound pressure at 10 m
(2)
dB(A)
60,0
60,5
61,0
61,5
62,5
62,5
63,0
63,0
63,5
Unit + Very Low Noise option
Sound power
(1)
dB(A)
90,0
90,0
91,0
91,0
92,0
92,0
92,5
93,0
93,0
Sound pressure at 10 m
(2)
dB(A)
57,5
57,5
58,5
58,5
59,5
59,5
60,0
60,5
60,5
Unit + Ultra Low Noise option
Sound power
(1)
dB(A)
87,5
88,0
89,0
89,0
89,5
90,0
90,5
90,5
91,0
Sound pressure at 10 m
(2)
dB(A)
55,5
56,0
57,0
57,0
57,5
58,0
58,5
58,5
59,0
Dimensions
Standard unit
Length
mm
4798 4798 7708 7708 7708 7708 10096 10096 10096
Width
mm
2253 2253 2253 2253 2253 2253 2253 2253 2253
Height
mm
2324 2324 2324 2324 2324 2324 2324 2324 2324
Unit + water buffer tank module option
(3)
mm
5992 5992 5992 5992 5992 5992 5992 5992 5992
Length
mm
5992 5992
-
-
-
-
-
-
-
Operating weight
(3)
Standard unit
kg
3180 3430 4787 4905 5344 5356 6308 6360 6859
Unit + Ultra Low Noise option
kg
3387 3661 5104 5222 5710 5722 6722 6774 7322
Unit + Ultra Low Noise + HP dual-pump hydraulic module option
kg
3658 3932 5494 5611 6178 6190 7191 7317 7865
Unit + Ultra Low Noise + HP dual-pump hydraulic Water
buffer tank module option
kg
4658 4932
-
-
-
-
-
-
-
Compressors
Hermetic Scroll 48.3 r/s
Circuit A/C
3
4
2/2
2/2
2/2
2/2
3/3
3/3
4/4
Circuit B/D
4
4
3/3
3/3
4/4
4/4
4/4
4/4
4/4
Number of power stages
7
8
10
10
12
12
14
14
16
Unit PED category
IV
IV
III
IV
IV
IV
IV
IV
IV
Refrigerant
(3)
R-32 / A2L/ GWP= 675 in accordance with ARI4
Circuit A/C
kg
29,0
35,0 16,0 /
16,0
18,0 /
18,0
18,0 /
18,0
18,0 /
18,0
29,0 /
29,0
29,0 /
29,0
35,0 /
35,0
tCO
2
e
19,6
23,6 10,8 /
10,8
12,2 /
12,2
12,2 /
12,2
12,2 /
12,2
19,6 /
19,6
19,6 /
19,6
23,6 /
23,6
Circuit B/D
kg
35,0
35,0 28,5 /
28,5
28,5 /
28,5
34,0 /
34,0
34,0 /
34,0
34,5 /
34,5
35,0 /
35,0
35,0 /
35,0
tCO
2
e
23,6
23,6 19,2 /
19,2
19,2 /
19,2
23,0 /
23,0
23,0 /
23,0
23,3 /
23,3
23,6 /
23,6
23,6 /
23,6
Oil
Circuit A/C
l
22,8
30,4 13,2 /
13,2
13,2 /
13,2
13,2 /
13,2
13,2 /
13,2
22,8 /
22,8
22,8 /
22,8
30,4 /
30,4
Circuit B/D
l
30,4
30,4 22,8 /
22,8
22,8 /
22,8
30,4 /
30,4
30,4 /
30,4
30,4 /
30,4
30,4 /
30,4
30,4 /
30,4
Capacity control
Connect’Touch
Minimum capacity
%
14
13
10
10
8
8
7
7
6
Condenser
Grooved copper tubes and aluminium fins
Fans
Axial with rotating impeller
Standard unit
Quantity
7
8
10
10
12
12
14
14
16
Maximum total air flow (cooling mode)
l/s
27510 31440 39300 39300 47160 47160 55020 55020 62880
Maximum rotation speed (heating mode)
r/s
12
12
12
12
12
12
12
12
12
Maximum total air flow (heating mode)
l/s
33740 38560 48200 48200 57840 57840 67480 67480 77120
Maximum rotation speed (heating mode)
r/s
16
16
16
16
16
16
16
16
16
Evaporator
Dual-circuit plate heat exchanger
Water volume
l
52,2
58,5
77,4
97,2
97,2
97,2
97,2 104,4
117
Max. water-side operating pressure without hydraulic module
kPa
1000 1000 1000 1000 1000 1000 1000 1000 1000
Hydraulic module (option)
Pump, Victaulic screen filter, relief valve, water and air vent valve,
pressure sensors
Pump
Centrifugal pump, monocell, 48.3 r/s, low- or high-pressure (as
required), single or dual (as required)
Expansion tank volume (Option)
l
80
80
-
-
-
-
-
-
-
Buffer tank volume (optional)
l
550
550
-
-
-
-
-
-
-
Max. water-side operating pressure with hydraulic module
kPa
400
400
400
400
400
400
400
400
400
Water connections with or without hydraulic module
Victaulic
®
type
Module 1/Module 2 connections
(a)
inches
4
4
4 / 4
4 / 4
4 / 4
4 / 4
4 / 4
4 / 4
4 / 4
Module 1/Module 2 external diameter
(a)
mm
114,8 114,9 114,3 /
114,3
114,3 /
114,3
114,3 /
114,3
114,3 /
114,3
114,3 /
114,3
114,3 /
114,3
114,3 /
114,3
Casing paint colour
Colour code RAL 7035 & 7024
(1) In dB ref=10
-12
W, (A) weighting. Declared dual-number noise emission value in
accordance with ISO 4871 with an uncertainty of +/-3 dB(A). Measured in
accordance with ISO 9614-1 and certified by Eurovent. Cooling mode operation.
(2) In dB ref 20 µPa, (A) weighting. Declared dual-number noise emission value in
accordance with ISO 4871 with an uncertainty of +/-3 dB(A). For information,
calculated from the sound power Lw(A).
(3) Values are guidelines only. Refer to the unit name plate.
(a) Modules 1 and 2 only relate to sizes 2300R to 4000R.
5 - PHYSICAL AND ELECTRICAL DATA FOR THE UNITS
EN-13
AQUACIAT
POWER
™ LD/ILD