ILD - ILDC - ILDH
350V
400V
500V
540V
600V
700V
702V
800V
900V
1000V
1100V
Cooling capacity
①
kW
92.8
105.2
128.1
139.9
155.3
163.1
183,4
201,8
239,8
257,9
278,8
Power input
kW
31.4
35.2
44.4
46.1
52.5
59.5
61,5
69,8
83,0
91,9
101,5
EER Efficiency
②
2.96
2.98
2.88
3.03
2.96
2.74
2,98
2,89
2,89
2,81
2,75
Seasonal efficiency ESEER
3.70
3.84
3.27
3.97
3.95
3.63
3.83
3.81
3.75
3.77
3.63
Lw / Lp
③
(High Perf. - HP)
dB(A)
89/57
90/58
91/59
92/60
Lw / Lp
③
(Low Noise version - LN)
dB(A)
83/51
85/53
87/55
Lw / Lp
③
(Xtra Low Noise version - XLN)
dB(A)
-
-
-
-
-
-
81/49
82/50
81/49
81/49
83/51
Heating capacity
①
kW
95.0
108.8
132.6
147.1
164.0
181.5
191,1
213,5
247,9
265,2
285,7
Power input
kW
31.4
36.0
43.1
47.7
53.0
57.1
63,2
71,5
82,7
89,9
97,1
Performances COP
②
3.03
3.02
3.07
3.08
3.09
3.12
3.02
2.99
3.00
2.95
2.94
Compressor
Hermetic SCROLL 2900 rpm
Starting mode
Direct in series
Quantity
2
2
2
4
4
4
4
4
4
4
4
Capacity control
%
100-57-
43-0
100-63-
37-0
100-50-0
100-78-
72-55-
50-45-
28-22-0
100-75-
50-25-0
100-78-
50-22-0
100-78-
71-57-
50-43-
28-21-0
100-81-
69-62.5-
50-37.5-
31-19-0
100-83-
66-55-
33-16-0
100-80-
70-60-
50-40-
30-20-0
100-77-
73-54-
50-45-
27-33-0
Refrigerant oil type
Polyolester POE 3MAF (32cst)
Oil volume
l
8.8
9.8
11.2
14.8
16.6
17.6
17.6
21.8
20.8
22.2
26.2
Refrig. circuit number
1
2
Refrigerant fluid (GWP)
R410A (1890)
Refrigerant load
kg
21
24
13.0
+13.0
18.0
+18.0
18.2
+19.2
18.0
+18.0
36.0
+37.0
Electric supply
ph/Hz/V
3~50Hz 400V (+6%/-10%) + Earth
Unit protection index
IP 44
Circuit control voltage
ph/Hz/V
1~50Hz 230V (+6%/-10%) - transformer mounted
Evaporator
Brazed plates type exchanger
Water content
l
8.68
9.88
10.66
12.48
15.42
15.42
15.8
15.8
18
20.4
20.4
Chilled water outlet min. / max.
°C
-10 / +18
-12 / +18
Hot water outlet min. / max.
°C
+30 / +50
Minimum water flow
m
3
/h
11.7
13.3
17.3
18.1
20.8
20.8
22,1
24,4
29,3
31,6
34
Maximum water flow
m
3
/h
30.7
34.6
41.9
45.9
50.7
50.7
63,2
69,5
77
77
77
Water connections
∅
Male G 2"1/2
Flange DN80
Flange DN100
Maximum pressure (water side)
bar
ILD 10 bars / ILDC-ILDH 4 bars
Air cooled condenser
Finned heat exchanger
Fan
∅
mm
800
Number x Motor rated power
High Performance series - HP
nb x kW
2x1.7
2x1.7
2x1.8
2x1.7
2x1.7
2x1.7
4x2.24
4x2.24
4x2.24
4x2.24
4x2.24
Number x Motor rated power
Low Noise series - LN
nb x kW
2x1.2
2x1.2
2x1.2
2x1.1
2x1.1
2x1.1
4x1.48
4x1.48
4x1.48
4x1.48
4x1.48
High Performance air flow - HP
m
3
/h
44000
42000
41000
44000
44000
44000
84300
Low Noise air flow - LN - XLN
m
3
/h
32000
29000
30500
35000
35000
35000
63180
Mini water content (ILD-ILDC)
l
220
213
357
164
207
203
213
212
213
290
364
Water tank content model H
l
250
500
Expansion vessel model C & H
l
18
34
Standard pump
n°
➃
Height without mounts
mm
2117
2117
2080 (+205 XLN)
Standard series length
mm
2190
2740
3698
C series length
mm
2190
2740
3698
H series length
mm
2190
2740
3698
Depth
mm
2129
2129
2200
Std range weight without charge
kg
1096
1195
1283
1570
1706
1878
2270
2320
2365
2445
2505
C range weight without charge
kg
1194
1292
1355
1675
1804
1976
2550
2600
2645
2725
2825
H range weight without charge
kg
1257
1356
1418
1748
1868
2040
2680
2730
2775
2855
2955
Storage temperature
°C
+ 50°C
47
Français
English
Deutsc
h
Español
Italiano
➀
Capacity for HIGH PERFORMANCE version based on:
a/ COOLING: +12°C/+7°C and condenser air inlet tempe35°C
b/ HEATING hot water 45°C and external air +7°C dry bulb 86%RH
➁
Gross EER or COP values
➂
Overall capacity level Lw, overall pressure level Lp at 10 metres, free field, in accordance with the ISO 3744 standard
➃
Depending on selection
(1) Capacity of the installation as a function of the expansion vessel mounted on the
unit. The auxiliary tank is already taken into account. In the case where the
installation capacity is higher, an expansion vessel must be added on the installation
corresponding to the surplus capacity.
(2) The water temperatures mentioned are the temperatures which can be reached
when the unit is stopped
Reversible unit - Heat pump technical specifications