EN
Product operating instructions
Working mode:
Heating
、
and Frying
Status definitions: the operation is the same for both left and right
burner.
The machine contains two independent heating units, each heating unit can be
individually switched and add or reduce power, a single burner maximum
heating power can be 2000W, when two burners at same time heating, the
internal controller will coordinate the burner within the sum of the power of not
more than 3500W, to ensure the safety of electricity.
The power allocation will follow the latter priority principle.
1. When the left burner heated with 2000W, press the right burner to 2000W,
the left burner will down to 1400W for heating, and the right burner will heat
with 2000W.
2. If th
e left burner on the “Temperature” function, the right burn can reach
2000W.
3. The operation is the same for both left and right burner.
If protocol anomaly, the max. limited power is 1600W for both left and right
burner.
The level of power
Power
Level
1
2
3
4
5
6
7
8
9
Power
display
200W
500W
800W
1000
W
1200
W
1400
W
1600
W
1800
W
2000
W
The level of temperature
Temper.
Level
1
2
3
4
5
6
7
8
9
10
Temper.
display
60
℃
80
℃
100
℃
120
℃
140
℃
160
℃
180
℃
200
℃
220
℃
240
℃
Power error range of -10% - +5%, burner less than 1000W will be heated by
intermittent with 1000W.
2000W will be heated with 2000W level, 10 minutes later will be down to
1800W for heating.
11