Operation
59
58
TDC26-TDC36-TM26GSM-TM66GSM-ERMES2- User’s manual
4.2.3
OUTPUT
COMMANDS
or
This gives access to interrogation and command of the outputs.If the combiner is
not allarmed and digit a code to acces,this is the voice othat appears on display:
!
Key in the code:
(Default MASTER code)
!
Press the button:
(
Output commands
)
!
This will be displayed:
At this point, use keys and to control the output according to its
programming (see para 3.6):
!
If the output is set to
“ON/OFF”
, the
key activates the output and the
key
deactivates it.
!
If the output is set to
“TOGGLE”
, both keys
and the
key invert the status
of the output
!
If the output is set to
“PULSE”
, both keys
and the
create a pulse on the
output.
!
If the output is also set on
"Input Refer."
,the operation of the keys
and
is
conditioned by the status of the input reference (see para 3.6.1 and 3.6.2).
In the installation example (see para 2.1), the relay of the electronic key and the
relay of the combiner are inter-connected to exchange so as to connect and
disconnect the anti-theft system through the two devices; indeed, in this way, the
inversion of status of each of the relays provokes the connection or disconnection of
the system
This implies, therefore, that the activation of the combiner relay DOES NOT
always correspond to the connection of the system
To carry out a connection command, it is therefore necessary to know the actual
status of the exchange through its output “+Int” connected to the input “INT” of the
combiner. In this manner, when keying
for connection, the combiner will exchange
the state of just relè if it centers it them will only turn out disinserita, otherwise not will
be effect; consequently it will not come visualized the relative message to the state of
the escape relè, but but the state of income "INT" from which the relè it depends, in
order to indicate the real state of the system. Therefore, if the display it visualizes:
This message will be relative to the “INT” input, and any command will simply correspond
to an inversion of the relay status, to display the resulting input status:
O u t
1
A n t i - t h e f t
N O
A n t i - t h e f t
O N
A n t i - t h e f t
O F F
4.2.4 INPUTS
STATUS
or
It approaches the visualization of the state of the input.
!
Key
in
the
code:
(Default
MASTER
code)
or
(Default COMMANDS code)
!
Press the button:
(
Inputs status
)
!
This will be displayed
Use keys
or
or key
or
directly to display IN1 and IN2.
Use keys
or
or key
or
directly to display INT1 and INT2.
4.2.5
OUT
OF
ORDER
With this command, the combiner will reset all the alarm cycles to zero and does
not accept any further activations. Any telephone call in progress at the time of the
command will not be interrupted, but continues as normal until its normal conclusion.
The other functions of the combiner remain operative, including responding to
outside calls, and the command and interrogation of the inputs and the outputs.
!
Digitare il codice:
(Default MASTER code)
!
Press the button:
(
Out of order
)
!
This will be displayed for some second:
NOTE: This command is only executable by keying in the MASTER code.
NOTA:
This command is only executable by keying in the MASTER
code.
.
I n K 1
I r r i g a t i o n N O
O U T
O F
O R D E R
2 3 ¥ I T I M
O U T O F O R D E R
Description of the stages of the input and outputs (see para 3.4)