Programmable DC Power Supply 62000P Series Operating & Programming Manual
*RCL
Recall Instrument State Command
Type:
Device status
Description:
This command restores the High Slew Rate Load to a state that was
previously stored in memory with the *SAV command to the specified
location (see *SAV).
Syntax:
*RCL <NRf>
Parameter:
1 to 101
Example:
*RCL 50
*RST
Reset
Command
Type:
Device status
Description:
Reset System
Syntax:
*RST
Parameter:
None
*SAV Save
Command
Type:
Device status
Description: This command stores the present state of the single 62012P Series and the
states of the current mode in a
specified location in memory.
Syntax:
*SAV
Example:
*SAV
*SRE
Service Request Enable Command/Query
Type:
Device status
Description:
This command sets the condition of the Service Request Enable
register, which determines which events of the Status Byte register (see
*STB) are allowed to set the MSS (Master Status Summary) bit. A "1" in
the bit position enable bits are
logically ORed to cause Bit 6 (the Master
Summary Status Bit)
of the Status Byte register to be set. See Status Byte
register for detail description.
Syntax:
*SRE <NRf>
Parameter:
0 to 255
Example:
*SRE 20
Enable the CSUM and MAV bit of the Service Request.
Query Syntax: *SRE?
Return Parameter: <NR1>
Query Example: *SRE?
Return the current setting of Service Request Enable.
*STB?
Read Status Byte Query
Type:
Device status
Description:
This query reads the Status Byte register. Note that the MSS
(Master
Summary Status) bit instead of RQS bit is returned in
Bit 6. This bit
indicates if the High Slew Rate Load has at least one
reason for requesting
service. *STB? does not clear the Status
Byte register, which is cleared
only when subsequent action has
cleared all its set bits.
Query Syntax: *STB?
Return Parameter: <NR1>
Query Example: *STB?
Return the contents of Status Byte.
Return Example: 20