Section 4: Specifications
TVC-1211 User Manual
4-3
020-100769-01 Rev. 4 (05-2012)
4.2
Power Requirements
4.2.1 Main Chassis
• Standard
460W Custom PSU (Active PFC)
• Rated input voltage
100 to 240 VAC
• Rated input frequency
50/60 Hz
• Rated input current
6.0-3.0A
• Rated input power
460W
• Input voltage range (Vrms)
100 to 240
• Frequency range Hz (Nominal)
50/60
4.2.2 Expansion Chassis
• Standard (16 slot/13 slot)
100-120/200-240VAC ±10%
• Range input voltage
100 to 240VAC
• Rated input frequency
47/63Hz
• Rated input current
8.0-4.0A
• Rated input power
500W
• Redundant
3 active & 1 redundant
• Hot swappable
Yes
Table 4.1 Nominal Input Voltage Values
Nominal Input Voltage (Vrms)
100
120
200
208
220
230
240
Max. Rated Output Wattage Rating
460
460
460
460
460
460
460
Nom. Input Current (A rms)
5.5
4.5
2.69
2.5
2.4
2.3
2.2
Max. Rated Input Wattage Rating
(Watts)
526
520
505
505
503
503
503
Max. Rated VA (Volt-Amp)
548
542
527
527
524
524
524
Efficiency (%)
87.5
88.5
91
91
91.5
91.5
91.5
Power Factor
0.97
Leakage Current (mA)
0.42
0.50
0.83
0.87
0.92
0.96
1.00
Max. Inrush Current (A peak)
30
Max. Inrush Current Duration (ms)
20
Max. British Thermal Unit Rating
(BTU-Hr)
1794
1773
1725
1725
1715
1715
1715