Temperature Group (SST+TEMP?)
The Temperature Group provides values and fault conditions for temperature-related items in Christie
.
#
Status
State Value
Description
2
4
6
10
11
12
14
20
29
123
124
Air Intake Temperature
Main Control Board Temperature
Image Processor Scaler Temperature
Formatter-Red Temperature
DMD Waterblock Temperature
Formatter-Green Temperature
Formatter-Blue Temperature
Housekeeping Board Temperature
Main Control Board FPGA Temperature
VOM FPGA Temperature
Power Supply Temperature
<value> °C
Displays the current
temperature of the sensor.
Unknown
Temperature reading is
unavailable.
<value> °C - Low
Temperature
Temperature is sitting inside
the warning band.
<value> °C - High
Temperature
Temperature is sitting inside
the warning band.
<value> °C - Too Hot
(shutdown)
Temperature is exceeding the
error threshold.
Communication Fault
(shutdown)
Cannot retrieve the
temperature from sensor.
<value> °C - Too Cold
(shutdown)
Temperature is below the
error threshold.
Cooling Group (SST+COOL?)
The Cooling Group provides values and fault conditions related to cooling and fans for Christie TruLife
+.
#
Status
State Value
Description
3
6
Formatter-Green (Fan 4)
Cave Blower Fan (Fan 102)
<tach> RPM
Displays the current tachometer
reading, if fan has not gone
through fan calibration step.
<%max>% - <tach> RPM
Displays current tachometer
reading and percentage of
maximum speed determined at
calibration.
Off
Fan is off.
Unknown
The tachometer reading is
unavailable.
Off - Overridden
Fan is off. The fan speed has been
changed from its default
recommended value.
<tach> RPM - Overridden
Fan is on. The fan speed has been
changed from its default
recommended value.
Christie status system
Christie Technical Reference–Status System
20
020-103327-03 Rev. 1 (04-2021)
Copyright
©
2021 Christie Digital Systems USA, Inc. All rights reserved.