Status
State Value
Description
27
Power Supply Input Voltage
OK
The power supply input voltage is OK.
AC Input Low
Displayed when the AC input is less than
180 VAC.
AC Input Failure
Displayed when the AC input is less than
85 VAC or the power is completely lost.
29
Lens ID
Detected
Detected the lens.
Unknown
Cannot determine the state of the lens
as the communication path to the lens is
not working.
Not Detected
Cannot detect the lens.
30
Main Control Board
OK
The main control board has been
initialized at least once and is known to
be OK.
Unknown
Cannot determine the main control
board status because it has not been
powered up.
Initialization Fault
Cannot successfully program the main
control board.
32
Power Supply Output Voltage
<value>V
Displays the output voltage from the
power supply. This value is typically 54V.
46
Status LED Board
OK
The status of the status LED board (SLB)
is OK.
Unknown
Cannot determine the status of the
status LED board (SLB) because the
backpane (C4BP) is nonfunctional.
Communication Fault
Cannot communicate with the status LED
board (SLB).
47
Side Panel NFCT
OK
The side panel NFCT is OK.
Unknown
The side panel NFCT status is unknown
because the integrated keypad board
(IKB) is non-functional.
Not Detected
Cannot detect the side panel NFCT.
50
51
52
Formatter-Red
Formatter-Green
Formatter-Blue
Off
The formatter is in standby without any
cached errors or warnings.
OK
Properly detected and initialized the
formatter.
Christie status system
Christie Technical Reference–Status System
8
020-103327-03 Rev. 1 (04-2021)
Copyright
©
2021 Christie Digital Systems USA, Inc. All rights reserved.