background image

For the most current technical documentation, visit www.christiedigital.com. 

Christie Digital Systems Canada Inc.
ph: 519 744 8005

Christie Digital Systems USA, Inc.
ph: 714 236 8610

Corporate of

 ces

United Kingdom
ph: +44  (0) 118 977 8000

Middle East
ph: +971 (0) 503 6800

Spain
ph: +34 91 633 9990

Singapore
ph: +65 6877 8737

Africa
ph: +27 (0)11 510 0094

Korea (Seoul)
ph: +82 2 702 1601

Japan (Tokyo)
ph: 81 3 3599 7481

India
ph: +91 (080) 6708 9999

Germany
ph: +49 (0) 221 99512 0

Russia
ph: +36 (0) 1 47 48 100

China (Shanghai)
ph: +86  21 6030 0500

China (Beijing)
ph: +86 10 6561 0240

Brazil
ph: +55 (11) 2548 4753

Australia
ph: +61 (0) 7 3624 4888

Worldwide of

 ces

Italy
ph: +39 (0) 2 9902 1161

Independent sales 
consultant of

 ces

Mexico
ph: +52 55 4744 1790

United States (Arizona)
ph: 602 943 5700

Columbia
ph: +57 (318) 447 3179

Summary of Contents for TruLife+

Page 1: ...Technical Reference 020 103327 03 Christie TruLife Status System ...

Page 2: ...the continued and proper operation of your product Failure to perform maintenance as required and in accordance with the maintenance schedule specified by Christie will void the warranty REGULATORY The product has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmf...

Page 3: ...System Group SST SYST 5 Signal Group SST SIGN 10 Illuminator Group SST LGHT 13 Version Group SST VERS 18 Temperature Group SST TEMP 20 Cooling Group SST COOL 20 Serial Group SST SERI 22 Christie TruLife Technical Reference Status System 3 020 103327 03 Rev 1 04 2021 Copyright 2021 Christie Digital Systems USA Inc All rights reserved ...

Page 4: ... guide applies to the following models Griffyn 4K32 RGB Product documentation For installation setup and user information see the product documentation available on the Christie website Read all instructions before using or servicing this product 1 Access the documentation from the Christie website Go to this URL http bit ly 3powZic or https www christiedigital com products projectors all projecto...

Page 5: ...or Unknown The storage device containing the information is inaccessible or the data on the device is corrupted System Group SST SYST The System group provides values and fault conditions relating to the system and its health for Christie TruLife Status State Value Description 0 Projector Hours hours minutes Displays the total amount of time that the projector has been on including warm up and coo...

Page 6: ...eset or calibration an error was detected related to the motor and or sensor 9 Built In Self Test N A The built in self test has not been executed yet Passed The built in self test completed successfully Failed The built in self test failed 10 System ID Board OK Properly detected and initialized the device Unknown Cannot determine the status of the device Communication Fault Cannot communicate wit...

Page 7: ...ding correctly Upgrade Failed The device failed to upgrade properly 13 Power Supply OK Detected the power supply and the output stage is on Off The power supply output stage is off Unknown Cannot determine the status of the power supply due to an upstream communication fault Communication Fault Cannot detect the power supply due to a communication failure Failed A non catastrophic error occurred S...

Page 8: ...wer Supply Output Voltage value V Displays the output voltage from the power supply This value is typically 54V 46 Status LED Board OK The status of the status LED board SLB is OK Unknown Cannot determine the status of the status LED board SLB because the backpane C4BP is nonfunctional Communication Fault Cannot communicate with the status LED board SLB 47 Side Panel NFCT OK The side panel NFCT is...

Page 9: ...t limit switches Cannot detect shutter status When the power state is off an error state prevents power up 96 Power Supply Output Current value A Displays the output current from the power supply This value depends on the current drawn from the supply and is informational only 100 Rotating Diffuser value RPM The diffuser is spinning at more than 500 RPM Off The diffuser is off Unknown Displayed if...

Page 10: ...Fault Cannot read the device hardware information Initialize Fault Cannot properly initialize the device Communication Fault The device failed to respond or provided a bad response to a command while the projector is in Standby mode Signal Group SST SIGN The Signal group provides values and fault conditions relating to the video signal status for Christie TruLife Status State Value Description 50 ...

Page 11: ...s not connected to the projector alias IP Displays the alias IP address of the SDVoE used to communicate with the projector over the SDVoE network 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 5011 5012 5013 5014 5015 5016 HDMI Port 1 HDMI Port 2 SDI Port 1 SDI Port 2 SDI Port 3 SDI Port 4 DP Port 1 DP Port 2 DP Port 3 CVOF Port 1 CVOF Port 2 CVOF Port 3 CVOF Port 4 SDVoE Port HDBaseT Input VO...

Page 12: ...eceiving video LED is green Incoming video ignored Video ignored LED is red 5018 ChristieLink 2 N A Port is off projector powered down LED is off Ready for plug in Christie Link is ready to be plugged in LED is off Waiting on peer Christie Link is waiting on the other side of the connection LED is yellow Link established Christie Link connection is established LED is white Transmitting video Chris...

Page 13: ...s have cooled down sufficiently 100 Main Code CRC OK The CRC is OK 101 CPU Temperature value C Displays the CPU temperature in Celsius value C Temperature exceeds the warning threshold 102 CSB Temperature value C Displays the CSB temperature in Celsius 103 LiteLOC OK LiteLOC is enabled and OK Not Active LiteLOC is disabled Not Reachable LiteLOC may not be able to reach brightness or color targets ...

Page 14: ...e wired correctly description of failure Lasers are wired incorrectly and cannot power on 110 Laser Reds value Displays the health status of the red lasers 111 Laser Greens value Displays the health status of the green lasers 112 Laser Blues value Displays the health status of the blue lasers 113 Laser Tecs value Displays the health status of the TECs 114 Laser Cold Plate Temp value C Displays the...

Page 15: ...22 Laser Boot SW Version version Version is OK invalid version number A version mismatch exists 123 Laser Main SW Version version Version is OK invalid version number A version mismatch exists 124 Laser UCD SW Version version UCD version is OK invalid version number At least one UCD version mismatch exists upgrade failed 125 Laser HKB FPGA Version version Housekeeping board HKB FPGA version is OK ...

Page 16: ...6 serial number is missing 156 SLBD RGB S N serial number Displays the status light board SLBD RGB serial number invalid serial number Status light SLBD RGB serial number is missing 161 to 184 Laser Red Bank X Temps value C Displays the current temperature of the sensor value C Temperature exceeds the warning threshold Laser Red Driver X Amps value A Displays the current amperage of the sensor val...

Page 17: ...erature exceeds the warning threshold Laser Blue Driver X Amps value A Displays the current amperage of the sensor value A Amperage exceeds the warning threshold Laser Blue Driver X Volts value V Displays the current voltage of the sensor value V Voltage exceeds the warning threshold Laser Blue Driver X Temp value C Displays the current temperature of the sensor value C Temperature exceeds the war...

Page 18: ...n the main control board Unknown Cannot determine the software version information 1 Main Control Board HW Version name level mod name Short name of the board level Version of the board mod Modification level of the board Detection Fault Failed to read the board type information 4 5 6 Formatter Red HW Version Formatter Green HW Version Formatter Blue HW Version name level mod name Short name of th...

Page 19: ... hardware version as the board is not ready 59 Photon SW Version major minor mod Rev Boot major minor mod Rev Main Displays the Photon bootloader software version and Photon Main firmware software version Unknown Cannot communicate with the Photon module or programming firmware 68 VOM HW Version name level mod name Short name of the board level Version of the board mod Modification level of the bo...

Page 20: ...the error threshold Communication Fault shutdown Cannot retrieve the temperature from sensor value C Too Cold shutdown Temperature is below the error threshold Cooling Group SST COOL The Cooling Group provides values and fault conditions related to cooling and fans for Christie TruLife Status State Value Description 3 6 Formatter Green Fan 4 Cave Blower Fan Fan 102 tach RPM Displays the current ta...

Page 21: ... if fan has not gone through fan calibration step max tach RPM Displays current tachometer reading and percentage of maximum speed determined at calibration Off Fan is off Unknown The tachometer reading is unavailable Off Overridden Fan is off The fan speed has been changed from its default recommended value tach RPM Overridden Fan is on The fan speed has been changed from its default recommended ...

Page 22: ...e S N serial number Displays the electronic serial number of the formatter N A The information is not currently available card not present or not powered Missing S N Cannot retrieve the value because the serial number was not programmed into the board correctly 14 15 Housekeeping Board S N Keypad Display S N serial number Displays the electronic serial number of the board Unknown The serial number...

Page 23: ... the value because the serial number was not programmed into the board correctly Christie TruLife status system Christie TruLife Technical Reference Status System 23 020 103327 03 Rev 1 04 2021 Copyright 2021 Christie Digital Systems USA Inc All rights reserved ...

Page 24: ...ingapore ph 65 6877 8737 Africa ph 27 0 11 510 0094 Korea Seoul ph 82 2 702 1601 Japan Tokyo ph 81 3 3599 7481 India ph 91 080 6708 9999 Germany ph 49 0 221 99512 0 Russia ph 36 0 1 47 48 100 China Shanghai ph 86 21 6030 0500 China Beijing ph 86 10 6561 0240 Brazil ph 55 11 2548 4753 Australia ph 61 0 7 3624 4888 Worldwide offices Italy ph 39 0 2 9902 1161 Independent sales consultant offices Mexico...