Section 2: Adjust the Image
Solaria One/Solaria One
+
Service Manual
2-9
020-101039-02 Rev. 1 (06-2013)
a. On the touch panel controller (TPC), tap the
Test Pattern
icon (
)
in the task bar.
b. Tap
All Test Patterns
.
c. Tap
RBG-12bit-Full Screen White
.
5. Measure the color point of the pattern with the spectroradiometer and verify that the values are within
these tolerances:
If the values are outside the tolerances:
a. Remove the top lid. See
Remove the Top Lid on page 3-4
b. Remove the screw holding the yellow notch filter cover.
Note:
Two different yellow notch filter assemblies are used in the Solaria One and Solaria One
+
pro-
jectors; version A and version B. Version B allows greater adjustment of the yellow notch filter and a
cut out holds the adjustment lever in position.
c. Adjust the position of the yellow notch filter:
• For version A, loosen the set screw and then manually rotate the yellow notch filter. Tighten the set
screw when the adjustment is complete.
• For version B, loosen or tighten the set screw to increase or decrease the angle of the yellow notch
filter.
Color
X
Tolerance
Y
Tolerance
Red
0.640
+/- 0.002
0.320
+/- 0.002
Green
0.280
+/- 0.002
0.640
+/- 0.002
Blue
0.160
+/- 0.002
0.100
+/- 0.002
White
0.314
+/- 0.002
0.351
+/- 0.002