Solaria One/Solaria One
+
Service Manual
2-1
020-101039-02 Rev. 1 (06-2013)
2 Adjust the Image
This section provides information and procedures for adjusting the projector image.
2.1
Rotate the Integrator Rod
UV HAZARD! When servicing the projector with the top lid removed anyone within the
immediate vicinity must wear safety glasses with side shields.
Whenever the integrator module is moved or replaced, its rotation must be corrected for proper focus and full
illumination of the three digital micromirror devices (DMDs).
1. Display a full white field test pattern:
a. On the touch panel controller (TPC), tap the
Test Pattern
icon (
)
in the task bar.
b. Tap
All Test Patterns
.
c. Tap
RGB-12bit-Full Screen White
.
2. Remove the top lid. See
Remove the Top Lid on page 3-4
3. Put on a pair of heat resistant gloves and UV resistant glasses.
4. Open the integrator rod access door (
A
).
5. Loosen the 2 integrator rod set screws (
A
) and (
B
).
A
A
B