Setting the power management parameters
In
Configuration
>
Power Management
, configure the following:
•
LCD Backlight—
The backlight for the LCD has three states.
Always On
,
Always Off
, or
Timer
. The backlight turns on again when any key on the LCD is pressed or if an alarm is
raised.
•
LCD Backlight Timer—
Sets how long the LCD backlight stays on (in seconds) when in timer
mode.
•
LCD Backlight Level—
Sets the LCD backlight brightness level. Maximum 25/Minimum 0.
•
Auto Power Up—
If there is an AC power interruption, while Auto Power Up is enabled, the
projector resumes operation in the same state as it left off. If the lamps are on and an image
showing when AC power is lost, the projector automatically powers back up with the lamps on
and an image shows when AC is restored.
•
Auto Shutdown Enable—
When Auto Shutdown Mode has been selected, and no projector
activity has been seen for the activation time-out period, the projector enters a power saving
mode in which the lamps dim and the shutter closes.
If this condition persists for an additional time-out period, the projector automatically goes to
Standby mode. The presence of any activity within this combined interval cancels Auto
Shutdown and returns the projector to normal operation.
•
Turn Off Image After (Min)—
Sets the activation interval (in minutes) for Auto Shutdown. If
all activity (input signals, web or serial port activity, key presses) is lost for this length of time,
and Auto Shutdown is enabled, an Auto Shutdown cycle begins.
•
Enter Standby After (Min)—
Sets the interval (in minutes) between starting Auto Shutdown
and entering Standby mode. Once Auto Shutdown has been entered, and all activity continues
to be absent for this interval, the projector automatically enters power Standby mode.
•
Lamp Regeneration Start Time—
Sets the time of day (in 24 hour format) when the
regeneration cycle starts. For 24/7 operation, the lamp regeneration cycle is required or lamp
life is reduced.
In Dual Lamp mode, the cycle is performed on each lamp separately. The second lamp waits for
the first lamp to come back on before it begins the cycle. In single lamp mode, the projector
goes into Standby mode for the regeneration cycle. The regeneration cycle runs for 15 minutes
C
These sections provide list selections.
I
Power section contains an On and Off button.
Only one is enabled depending on the current
powered state of the projector.
D
Primary Tabs located along the top of the Main
window.
J
Shutter section contains an Open and Close
button. Only one is enabled depending on the
current state of the projector’s shutter.
E
Current Status Bar provides information
messages according to the current status of
the projector.
K
On-screen display section contains an On and Off
button. Only one is enabled depending on the
current state of the projector’s on-screen
display.
F
Projector Information section is read-only.
—
http://www.pureglare.com.au