LHD700 User Manual
020-000422-01 Rev.1 (11-2011)
Maintenance and Care
The WARNING indicators show the state of the function which protects the projector. Check the state of the
WARNING indicators and the POWER indicator to take proper maintenance.
The projector is shut down and the WARNING TEMP .
indicator is blinking red .
When the temperature inside the projector reaches a
certain level, the projector will be automatically shut down
to protect the inside of the projector. The POWER indicator
is blinking while the projector is being cooled down. When
the projector has cooled down enough (to its normal
operating temperature), it can be turned on again by
pressing the ON/STAND-BY button.
Note:
The WARNING TEMP. indicator continues to blink
even after the temperature inside the projector returns
to normal. When the projector is turned on again, the
WARNING TEMP. indicator stops blinking.
Then check the matters below:
– Did you provide appropriate space for the projector to be
ventilated? Check the installing condition to see if the air
vents of the projector are not blocked.
– Has the projector been installed near an Air-Conditioning/
Heating Duct or Vent? Move the installation of the
projector away from the duct or vent.
– Is the filter clean? Replace the filter with a new one.
The projector is shut down and the LAMP/SHUTTER
indicator is lighting and other indicators are blinking .
When the projector detects an abnormal condition, it
will be automatically shut down to protect the inside
of the projector and the LAMP/SHUTTER indicator
lights on and other indicators blink. In this case, unplug
the AC power cord and plug it, and then turn on the
projector once again to verify operation. If the projector
cannot be turned on and these indicators are still
lighting and blinking, unplug the AC power cord and
contact the service center.
CAUTION
DO NOT LEAVE THE PROJECTOR WITH THE
AC POWER CORD CONNECTED UNDER AN
ABNORMAL CONDITION. IT MAY RESULT IN
FIRE OR ELECTRIC SHOCK.
Top Panel
LAMP/SHUTTER indicator lights
on and other indicators blink .
Top Panel
WARNING TEMP .
blinking red
Warning Indicators
77
Downloaded From projector-manual.com Christie Manuals