For US and international hazard distances based upon IEC 62471-5:2015, Photobiological Safety of
Lamps and Lamp Systems – Part 5: Image Projectors.
Projection lens
Part number
Hazard distance
(m)
0.72:1 HB fixed
144-110103-XX
1.0
0.9:1 HB fixed
144-111014-XX
1.0
1.13-1.31:1 HB zoom
144-103105-XX
1.0
1.13-1.66:1 HB zoom
144-129103-XX
2.0
1.31-1.63:1 HB zoom
144-104106-XX
2.0
1.45-2.17:1 HB zoom
144-130105-XX
2.5
1.63-2.17:1 HB zoom
144-105107-XX
2.5
1.95-3.26:1 HB zoom
144-131106-XX
4.0
1.99-2.71:1 HB zoom
144-106108-XX
3.0
2.71-3.89:1 HB zoom
144-107109-XX
4.5
3.89-5.43:1 HB zoom
144-108100-XX
6.5
0.72:1 UHC fixed
163-116109-XX
1.0
0.9:1 UHC fixed
163-117100-XX
1.0
1.13-1.66:1 UHC zoom
163-118101-XX
2.0
1.45-2.17:1 UHC zoom
163-119102-XX
2.5
1.95-3.26:1 UHC zoom
163-120103-XX
3.5
2.71-3.89:1 UHC zoom
163-121105-XX
4.6
3.89-5.43:1 UHC zoom
163-122106-XX
6.6
For Installations in the United States
The following must be in place for laser-illuminated projector installations in the United States:
•
Any human access to the hazard zone, if applicable, must be restricted by barriers to enforce
the no access zone.
•
Permanent show installations containing Risk Group 3 laser-illuminated projectors must meet
the following conditions:
•
Installed by Christie or by Christie-authorized and trained installers.
Refer to the Laser Illuminated Projector - Class 1 Risk Group 3 Installation training (Course
code: CF-LIPI-01) on the http://www.christieuniversity.com site.
•
Performed according to instructions provided by Christie.
•
Ensure the projection system is securely mounted or immobilized to prevent unintended
movement or misalignment of the projections.
•
A copy of the FDA variance approval letter must be with the operator or other responsible
individual.
Introduction
4K40-RGB Installation and Setup Guide–D4K40-RGB, Roadie 4K40-RGB
10
020-102961-03 Rev. 1 (08-2019)
Copyright
©
2019 Christie Digital Systems USA, Inc. All rights reserved.