Examples
Send a ping:
(PNG?)
Result:
(PNG!71 001 000 234)
Indicates Series 4 cinema projector type, software: 1 major, 0 minor, 234 beta.
Determine build number:
(PNG+BILD?)
Result:
(PNG+BILD!00044)
Indicates build number 44.
PWR–Power
Changes the power state of the product.
Parameters
•
Access Level: Operator
•
Power level (minimum): Power Down
Commands
Command
Description
Values
PWR?
Returns the current power state
of the projector. (Read-only)
—
PWR <mode>
Changes the power mode.
0 = Turns the projector on and the light source off
1 = Turns the projector and light source on
3 = Sets the projector to standby mode
10 = Cool down lamp—projector stays in cooling down mode
for 10 minutes after the light source is turned off (Read-only)
11 = Warm up—middle status between standby and full
power mode (Read-only)
PWR+COOL?
Returns the status of the current
cooling down timer. (Read-only)
—
PWR+STAT?
Returns the status of the current
power state. (Read-only)
—
Examples
Return the target power state from the latest command sent to the projector:
(PWR?)