(LPF!L001 001 006 "Default")
(LPF!L001 001 007 "Default3D")
(LPF!L001 001 008 "Laser_Bhavana002")
(LPF!L001 001 009 "Laser_Bhavana_003")
(LPF!L001 001 010 "bhavana_008_laser")
(LPF!L111 "--END--")
LPM–Lamp Mode
Enables or disables LiteLOC
™
and sets its sensor level.
Parameters
•
Access Level: Operator
•
Power level (minimum): Power Up
Commands
Command
Description
Values
LPM?
Returns the lamp mode for the active lamp file. (Read-only)
—
LPM <value>
Sets LiteLOC sensor level for the active lamp file.
value = Numeric value
LPM <0 | 1>
Enables or disables LiteLOC for the active lamp file.
0 = Disables LiteLOC
1 = Enables LiteLOC
Examples
Return the lamp mode for the active lamp file:
(LPM?)
Result:
(LPM! "0 080")
Where 0 indicates LiteLOC is disabled and the sensor level is set to 80.
Enable LiteLOC and set its sensor level to 60:
(LPM 1 60)