background image

Wall / Ceiling  

Mounting  

Brackets

Extruded 

Aluminum  

Case

Removable Fascia

TOOLS REQUIRED

Overview -

 Components

 CAUTION 

Read and understand  

all warnings before  

beginning installation.

PLEASE READ -

 Safety Information

 WARNING   

Improper installation and use of the Acumen screen can result in serious injury or death. Primarily, injuries can occur if the unit falls due to imprecise 

installation, mishandling of the unit during installation, or installation on an insufficient wall or ceiling structure. Please use extreme care.

1. 

Please read the following installation guidelines thoroughly and follow them carefully. 

Failure to do so may cause product to fall or otherwise fail, and could result in serious injury.

2. 

Installation and calibration of the unit should only be performed by an authorized, qualified, 

and experienced professional. 

3. 

Do not affix the unit to walls or ceilings that have inadequate strength to permanently hold 

the unit during use. It is the owner’s and installer’s responsibility to confirm the wall or 

ceiling to which the unit attaches is sufficient to permanently hold the weight and stress 

loads of the unit at all times. Draper, Inc., is not responsible for improper installation, 

application, testing, or workmanship related to the product at place of installation.

4. 

It is the installer’s responsibility to make sure appropriate fasteners are used for mounting.

5. 

All hardware must be installed level. Unit must be level and square.

6. 

Never leave the area while operating the unit during installation, maintenance, or normal 

operation, unless it is secure and safe.

7. 

Before testing or operation, carefully inspect the entire area and path 

(especially 

underneath)

 of unit to be sure no persons or objects are in the area.

8. 

During testing or operation, carefully watch the surrounding area for any potential safety 

concerns including nearby persons or objects.

9. 

After installation, the entire system, including all sensors, should be carefully tested to 

ensure safe and normal operation. Extreme care should be taken during testing to remain 

clear of moving parts to avoid possible injury.

10. 

Operation of unit should be performed only by authorized and qualified personnel, who have 

been trained in its safe and effective operation and understand its safety features.

11. 

The safety features of the unit should never be disabled, bypassed, or overridden. The 

system should not be operated until all safety features are properly and completely 

installed, calibrated, and tested.

12. 

Unit may need to comply with local, state, or district rules and regulations, in particular 

when installed in schools. All applicable rules and regulations should be reviewed before 

installation and use.

13.  Failure to precisely follow installation guidelines invalidates all warranties.

14. 

Custom products/installations may not be reflected in this manual. Call Draper, Inc., if 

you have questions about the installation of custom products or any questions about your 

installation.

Before Beginning Installation

1. 

Look for any job site conditions that could interfere with installation or operation of 

the system.

2. 

Read carefully and be sure to understand all installation instructions and all 

related operations manuals. These instructions are intended to serve as a guide 

for the installer and owner. They should be followed closely and combined with the 

expertise of experienced qualified installers. Draper, Inc., is not responsible for 

improper installation, application, testing, or workmanship related to the product at 

place of installation. Please retain all instructions for future use.

3. 

Open cartons lengthwise.

4. 

Locate and lay out all pieces.

5. 

Inspect all boxes to make sure you have received the proper unit and parts. 

Controls may be shipped separately, or in same carton as unit.

6. 

If you have any difficulties with installing, servicing, or operating your unit, call your 

dealer or Draper, Inc., 765-987-7999.

Important Safety Information

Important Safety Information

POWER DRILL

PENCIL

TAPE MEASURE

HARDWARE

 (by others) 

LEVEL

HEX WRENCH

3

/

32

"

Draper, Inc.  |  411 S. Pearl St. Spiceland, IN 47385 

draperinc.com  |  765.987.7999  |  800.238.7999  

© 2020 All Rights Reserved 

FORM: Acumen_M_Inst20

Acumen

™ 

M

Manual projection screen

INSTRUCTIONS

INSTALLATION & OPERATION

If you have any difficulties installing or servicing your  

Acumen, call your dealer or Draper, Inc. 

Summary of Contents for Acumen M XT1000E

Page 1: ...ving parts to avoid possible injury 10 Operation of unit should be performed only by authorized and qualified personnel who have been trained in its safe and effective operation and understand its safety features 11 The safety features of the unit should never be disabled bypassed or overridden The system should not be operated until all safety features are properly and completely installed calibr...

Page 2: ...ION Product is very heavy Installer must provide adequate attachment hardware and anchors as required Installer must also ensure that structure is of adequate strength 2 Ensure that mounting brackets are level 3 Slide all Bracket Locks to the center of case 4 Holding the case by the endcaps lift it up and over the cleats on the mounting brackets see Fig 3 Wall Bracket Mounting Channels are shown i...

Page 3: ...EW ACUMEN Ceiling Mounting Bracket CEILING Figure 5 B Figure 5 A Slide to lock case to Bracket Slide to lock case to Bracket Wall Bracket Channels for Case Mounting 18 457mm Max Distance Optional Center Bracket One Ceiling Bracket Centered Figure 6 Carriage Bolt Washer Hex Nut ACUMEN Ceiling Bracket Assembly Ceiling Bracket Assembly Section 3 Fascia Removal To remove fascia 1 Remove the screws fro...

Page 4: ...4 1 2 114mm 5 15 16 151mm Centered Ceiling Bracket ACUMEN End of Case Dimensions Shown with Ceiling Bracket 1 44mm 20 507mm 4 102mm 16 406mm 16 406mm 24 610mm 12 305mm 8 203mm 4 102mm 6 171mm 4 7 16 113mm 19mm 3 89mm 3 9 16 90mm 2 70mm 4 15 16 125mm Mounting Hardware by others NOTE It is the responsibility of the installer to select mounting hardware appropriate for the mounting surface page 4 of ...

Reviews: