4-34
J Series 1000W and 1200W Service Manual
020-100725-04 Rev. 1 (07-2015)
Section 4: Parts and Module Replacement
11. Lock the setscrews, and re-check the boresight quality. Tighten the setscrew enough to make sure they will
not shift.
4.12.2 Convergence
UV Exposure - Protective UV glasses must be worn when performing
convergence adjustments.
Boresight must be correct before adjusting convergence. Do NOT adjust
plungers.
Observe all electrostatic precautions. Use a grounded wrist strap when
handling electronic assemblies.
NOTICE!
Adjusting convergence incorrectly may damage the projector light engine. Convergence should
only be adjusted by a Christie accredited service technician.
Convergence tool kit required: 003-000078-XX
A convergence problem is evident when 1 or more projected colors (red/green/blue) appears mis-aligned when
examined with a convergence test pattern. Normally all 3 colors should overlap precisely to form pure white
lines throughout the image. Convergence will be required when 1 or more individual colors appear adjacent to
some or all of the lines.
1. Power on the projector and let the lamp warm up for a minimum of 30 minutes.