Command
Description
Values
1000 (Default)
CCA+ROFB <value>
Manually adjusts the red portion of blue.
0 to 1000
0 (Default)
CCA+GOFB <value>
Manually adjusts the green portion of blue.
CCA+ROFW <value> Manually adjusts the red portion of white.
0 to 1000
1000 (Default)
CCA+GOFW <value> Manually adjusts the green portion of white.
CCA+BOFW <value> Manually adjusts the blue portion of white.
Examples
Turn on meter adjustment:
(CCA+MTRA 1)
Turn on automatic test patterns for manual adjustments:
(CCA+MNTP 1)
Set the measured intensity of red to 453:
(CCA+RDMI 453)
CCI–Color Temperature
Applies a predefined color temperature value to the input signal.
Commands
Command
Description
Values
CCI <value>
Applies a color temperature to the input signal.
0 = Warmest
1 = Warm
2 = Cool
3 = Bright color
Examples
Apply the warmest color temperature:
(CCI 0)
Serial API commands
GS Series 599 Serial Commands Technical Reference
17
020-102403-02 Rev. 1 (04-2017)