Command
Description
Values
1.000 (Default)
CCA+RDDX <value>
Specifies the x coordinate for red gain.
0.300 to 0.700
0.643 (Default)
CCA+RDDY <value>
Specifies the y coordinate for red gain.
0.300 to 0.500
0.344 (Default)
CCA+GNDG <value> Specifies the green gain.
0.200 to 1.000
1.000 (Default)
CCA+GNDX <value> Specifies the x coordinate for green gain.
0.300 to 0.400
0.544 (Default)
CCA+GNDY <value>
Specifies the y coordinate for green gain.
0.400 to 0.700
0.544 (Default)
CCA+BLDG <value>
Specifies the blue gain.
0.200 to 1.000
1.000 (Default)
CCA+BLDX <value>
Specifies the x coordinate for blue gain.
0.100 to 0.300
0.141 (Default)
CCA+BLDY <value>
Specifies the y coordinate for blue gain.
0.030 to 0.400
0.094 (Default)
CCA+WHDG <value> Specifies the white gain.
0.200 to 1.000
1.000 (Default)
CCA+WHDX <value> Specifies the x coordinate for white gain.
0.200 to 0.400
0.334 (Default)
CCA+WHDY <value> Specifies the y coordinate for white gain.
0.200 to 0.400
0.371 (Default)
CCA+MANA <0 | 1>
Enables or disables manual adjustment.
0 = Turns off manual adjustment (Default)
1 = Turns on manual adjustment
CCA+MNTP <0 | 1>
Turns automatic test patterns for manual
adjustment items on or off.
0 = Turns off automatic test patterns
1= Turns on automatic test patterns
(Default)
CCA+ROFR <value>
Manually adjusts the red portion of red.
0 to 1000
1000 (Default)
CCA+GOFR <value>
Manually adjusts the green portion of red.
0 to 1000
0 (Default)
CCA+BOFR <value>
Manually adjusts the blue portion of red.
CCA+GOFG <value>
Manually adjusts the green portion of green. 0 to 1000
1000 (Default)
CCA+ROFG <value>
Manually adjusts the red portion of green.
0 to 1000
0 (Default)
CCA+BOFG <value>
Manually adjusts the blue portion of green.
CCA+BOFB <value>
Manually adjusts the blue portion of blue.
0 to 1000
Serial API commands