![CHOWEL PATC--150A-EU Instruction Manual Download Page 60](http://html1.mh-extra.com/html/chowel/patc-150a-eu/patc-150a-eu_instruction-manual_2603266060.webp)
CHOWEL / PATC-150A-EU
- 51 -
7. Troubleshooting
7-1 External I/O checking
7-1-1 I/O indication in normal operation
The following table shows examples of the indicator of the welding controller and
the external I/O signal.
Use this table for troubleshooting.
Operation mode
Test mode
weld mode
operation status
Inactive
Active
Inactive
Active
a. POWER
indicator
ON
ON
ON
ON
b. PILOT INPUT
indicator
OFF
ON
OFF
ON
c. WELD/NO WELD
input indicator
OFF
OFF
ON
ON
d. EXTERNAL THERMO
input indicator
ON
ON
ON
ON
e. READY
indicator
OFF
OFF
ON
ON
f. FAULT INPUT
indicator
OFF
OFF
OFF
OFF
The WELD/NO WELD input indicator always indicates the external input signal
status, and therefore is not related to the WELD/NO WELD mode selector at the
TB-30 side.
7-1-2 I/O indication in abnormal operation
If the indication is not what expected identify, the cause and provide remedy as
follows,
a. The POWER indicator is not ON.
The power is not supplied to the power terminal 01 and 02.
Check the power line to the power terminal fittings and the ON status of the
circuit breaker, emergency stop s/w, or micro s/w if installed.
b. The PILOT input indicator is not ON.
The pilot input signal is not on. Check the wiring to the terminal block or I/O
connector and the signal source.
Summary of Contents for PATC--150A-EU
Page 20: ...CHOWEL PATC 150A EU 11 Pulsation 1 9 times...
Page 65: ...CHOWEL PATC 150A EU 56 1 Weld program sheet...
Page 67: ...CHOWEL PATC 150A EU 58 3 I O connection diagram...
Page 68: ...CHOWEL PATC 150A EU 59 4 RC 05 wiring diagram...
Page 69: ...CHOWEL PATC 150A EU 60 5 Outside view of PATC 150A EU...
Page 70: ...CHOWEL PATC 150A EU 61 6 Outside view of TB 30...
Page 71: ...CHOWEL PATC 150A EU 62 7 Outside view of RB 10...
Page 72: ...CHOWEL PATC 150A EU 63 8 Electrical connection for step down T R and SCR...