3-2-5 Alarm and Measurement function
. Monitors
: Welding current, Line voltage, T/R margin... various monitor items.
. Open of welding cable
: Notice by analysis measure of testing weld current.
3-2-6 Communication System
. Communication is available to monitor weld condition and results without
affecting machine operation.
3-2-7 Memory and Data
. Maintenance
: 5 years and more by Lithium battery.
3-3. TRANSFORMER Specifications
3-3-1. General Specification
Model
PATC-150A-EU
Rated Capacity(at the 50% D.C.)(KVA)
150
Rated input voltage(V)
380
Phase(Ø)
Single
Rated frequency(
㎐
)
50 / 60
Max. input capacity(KVA)
380
Max. short circuit current((KA)
16
Max. secondary output voltage(V)
23.75
Duty cycle(%)
7.8
Cooling water consumption(
ℓ
/min)
6 (quantity for only TR.)
Connection
hose size (inch×mm)
Air inlet
1/2" × Ø13
Water inlet
1/2" × Ø13
Water outlet
3/4" × Ø19
Output terminal distance for
kickless cable(mm)
27
Solenoid valve
4sets. DC 24V (2 Retract valve include)
Insulation classification
F
Summary of Contents for PATC--150A-EU
Page 20: ...CHOWEL PATC 150A EU 11 Pulsation 1 9 times...
Page 65: ...CHOWEL PATC 150A EU 56 1 Weld program sheet...
Page 67: ...CHOWEL PATC 150A EU 58 3 I O connection diagram...
Page 68: ...CHOWEL PATC 150A EU 59 4 RC 05 wiring diagram...
Page 69: ...CHOWEL PATC 150A EU 60 5 Outside view of PATC 150A EU...
Page 70: ...CHOWEL PATC 150A EU 61 6 Outside view of TB 30...
Page 71: ...CHOWEL PATC 150A EU 62 7 Outside view of RB 10...
Page 72: ...CHOWEL PATC 150A EU 63 8 Electrical connection for step down T R and SCR...