![CHOWEL PATC--150A-EU Instruction Manual Download Page 57](http://html1.mh-extra.com/html/chowel/patc-150a-eu/patc-150a-eu_instruction-manual_2603266057.webp)
CHOWEL / PATC-150A-EU
- 48 -
. SEQUENCE WHEN DETECTION IS MADE AFTER THE WELD
Pilot input
OFF
Valve output
OFF
Weld current
OFF
Weld complete output
If Weld Complete is ON
in case of fault
OFF
Fault output
OFF
Fault reset input
OFF
ISQ SQ US WT1 CT WT2
HT
ISQ : Initial Squeeze Time
CT : Cool Time
SQ : Squeeze Time WT2 : #2 Weld Time
US : Up Slope Time HT : Hold Time
WT1 : #1 Weld Time OT : Off Time(in repeat mode only)
Fig.6-7
Note : The above chart shows a case where pulsation is set for one time.
Summary of Contents for PATC--150A-EU
Page 20: ...CHOWEL PATC 150A EU 11 Pulsation 1 9 times...
Page 65: ...CHOWEL PATC 150A EU 56 1 Weld program sheet...
Page 67: ...CHOWEL PATC 150A EU 58 3 I O connection diagram...
Page 68: ...CHOWEL PATC 150A EU 59 4 RC 05 wiring diagram...
Page 69: ...CHOWEL PATC 150A EU 60 5 Outside view of PATC 150A EU...
Page 70: ...CHOWEL PATC 150A EU 61 6 Outside view of TB 30...
Page 71: ...CHOWEL PATC 150A EU 62 7 Outside view of RB 10...
Page 72: ...CHOWEL PATC 150A EU 63 8 Electrical connection for step down T R and SCR...