CHOWEL / PATC-150A-EU
- 24 -
Program No.
Inputs
PILOT 1 PILOT 2 PILOT 4 PILOT 8
1
1
0
0
0
2
0
1
0
0
3
1
1
0
0
4
0
0
1
0
5
1
0
1
0
6
0
1
1
0
7
1
1
1
0
8
0
0
0
1
9
1
0
0
1
10
0
1
0
1
11
1
1
0
1
12
0
0
1
1
13
1
0
1
1
14
0
1
1
1
Only when three PILOT INPUT signals are coincided with each other when
checked and confirmed in synchronization with the power supply, the sequence will
start.
-
WELD / NO WELD INPUT
When this input signal is ON, the operation mode is WELD, and when off,
NO WELD.
In the test mode, if the pilot signal is set at ON, the sequence will be in the
self-holding status.
Connect this signal to the weld sequence initiation signal.
When not used, keep this signal short-circuit to ON.
-
COUNT RESET
When this signal is turn ON, only the counter that has completed counting is
reset to 0 and the COUNT UP OUTPUT is turned to OFF.
Note that this signal is neglected while the sequence is active.
Connect this signal to reset the counter.
When not used, keep this signal open.
-
STEPPER RESET
When this signal is turned ON, the step no. and the step counter are reset and
the STEPPER COMPLETE OUTPUT is turned OFF.
Connect this signal to the signal that resets the stepper.
Note that this signal is neglected while the sequence is active.
When not used, keep this signal open.
Summary of Contents for PATC--150A-EU
Page 20: ...CHOWEL PATC 150A EU 11 Pulsation 1 9 times...
Page 65: ...CHOWEL PATC 150A EU 56 1 Weld program sheet...
Page 67: ...CHOWEL PATC 150A EU 58 3 I O connection diagram...
Page 68: ...CHOWEL PATC 150A EU 59 4 RC 05 wiring diagram...
Page 69: ...CHOWEL PATC 150A EU 60 5 Outside view of PATC 150A EU...
Page 70: ...CHOWEL PATC 150A EU 61 6 Outside view of TB 30...
Page 71: ...CHOWEL PATC 150A EU 62 7 Outside view of RB 10...
Page 72: ...CHOWEL PATC 150A EU 63 8 Electrical connection for step down T R and SCR...