Chore-Tronics Feeder Control
Wiring Diagrams
MT1559A
10/6/99
82
82
MT1559-16 3/99
DURING NON-ALARM CONDITIONS, THE C AND N.O.
CONTACTS OF THE ALARM RELAY ARE CLOSED.
DURING ALARM CONDITIONS, THE C AND N.C.
CONTACTS OF THE ALARM RELAY ARE CLOSED.
INPUT POWER BEING OFF IS AN ALARM CONDITION.
SEE NOTE 1
NOTES:
1.
I/O ADDRESS
FOR I/O NET
-24 VOLT DC
+24 VOLT DC
PUSH DOWN TO
OPEN TERMINAL
BLOCK
SUPPLY VOLTAGE
100 - 240 VAC
50/60 HZ. 0.6 AMP.
L2
SUPPLY
L1
24 VDC
GND
+
-
GROUND
+ -
24 VDC POWER SUPPLY
VOLTAGE INPUT RANGE:
100 - 240 VAC
50/60 HZ. SINGLE PHASE
0.6 AMP.
24V EXT GND
NC
NO
C
RELAY
ALARM
#1
- I/O +
FNET
NET
#4
#3
#2
#5 #6
230 VAC 50/60 HZ.
INCOMING POWER
L1 L2
D 1
WIRING DIAGRAM
SJB CONTROL
WIRING DIAGRAM
FEED CONTROL
120 OHM RESISTOR
REQUIRED AT THE
BEGINING AND END
OF THE I/O NET
GND.
120 OHM RESISTOR
- TO I/O NET
+ TO I/O NET
GND.
V
V
SIGN.
CONNECT THE REMAINING
LOAD CELL IN THE SAME
MANER.(MAX OF 6 LOADCELLS)
GREEN
RED
BLACK WHITE
SIGN.
SHIELD
120 OHM RESISTOR
TWISTED PAIR
I/O NET
+
-
F NET
SJB CONTROL
TO PC HOOK UP
(MUST HAVE C CENTRAL)
DRY CONTACTS
230 VAC 50/60 HZ
SUPPLY
TWISTED PAIR
LID
SWITCH
FEED
BACK
LID
SWITCH
FEED
BACK
+24 VOLT SUPPLY TO
SJB (MAX 6 CELLS)
120 OHM RESISTOR
INPUT FROM
WATER METER
-24 VOLT
SUPPLY TO
SJB (MAX 6
CELLS)
+ TO I/O NET
- TO I/O NET
SUPPLY VOLTAGE
100 - 240 VAC
50/60 HZ. 0.6
AMP.
I/O BOARD WIRING
WATER
METER
24 VDC POWER SUPPLY
VOLTAGE INPUT RANGE:
100 - 240 VAC
50/60 HZ. SINGLE PHASE
0.6 AMP.
SUPPLY
L1
24 VDC
-
GND
+
L2
-
-24 VOLT DC
GROUND
+24 VOLT DC
PUSH DOWN TO
OPEN TERMINAL
BLOCK
+
WHITE
BLACK
RED
SHIELD
GREEN
V
V
GND.
+
-
GND.
- TO I/O NET
SIGN.
SIGN.
GND.
+ TO I/O NET
120 OHM RESISTOR
120 OHM
RESISTOR
SJB CONTROL
I/O ADDRESS
FOR I/O NET
-
+
SJB CONTROL
WIRING DIAGRAM
-
+
#6
#5
#7
#5
#6
#7
#8
#8
L3
T3
L2
L1
T1
T2
#1
#3
#4
#1
#2
#3
#4
CONTACTOR
NOT SUPPLIED
WEIGH
BIN #2
RELAY BOARD
1 HP MAX
FEEDER
#2
FEEDER
FILL #2
WATER
CLOCK
230 VAC
SUPPLY
M
MOTOR FOR
#2 WEIGH-BIN
FILL AND
SCREENER
FEEDER
FILL #1
WEIGH
BIN #1
LIGHT
FEEDER
#1
CONNECT THE REMAINING
LOAD CELL IN THE SAME
MANER.(MAX OF 6 LOADCELLS)
230 VAC
SUPPLY
L2
L3
L1
T3
T1
T2
T3
T2
T1
L3
L2
L1
#1
#2
#3
#1
#2
#3
#4
#4
TYPICAL CONTACTOR
MOTOR FOR
#1 WEIGH-BIN
FILL AND
SCREENER
230 VAC
SUPPLY
M
230 VAC
SUPPLY
CONTACTOR
NOT SUPPLIED
FEEDER
FILL #1
WEIGH
BIN #1
FEEDER
#1
LIGHT
CONNECTION
T3
L3
L2
L1
L3
L3
L1
L2
T1
T3
T2
T2
T3
T1
L2
L1
T2
T1
L3
T3
L2
T2
L3
T3
L1
T1
L2
T2
L1
T1
MOTOR FOR
#1 FEEDER
LOAD CELLS
UNDER WEIGH BIN
LOAD CELLS
UNDER WEIGH BIN
LOAD CELLS
UNDER WEIGH BIN
EXAMPLE 11
EXAMPLE 8
LOAD TO
LIGHTS
M M
230 VAC
SUPPLY
M
230 VAC
SUPPLY
M
CONTACTOR
NOT SUPPLIED
CONTACTOR
NOT SUPPLIED
MOTOR FOR
#1 FEEDER
FILL
M M
CONTACTOR
NOT SUPPLIED
CONTACTOR
NOT SUPPLIED
CONTACTOR
NOT SUPPLIED
TO WATER
SOLENOID
M
M
M
POWER SUPPLY
FOR WATER
SOLENOIDS
M
230 VAC
SUPPLY
M
MOTOR FOR
#2 FEEDER
MOTOR FOR
#2 FEEDER FILL
M
+ TO I/O NET
- TO I/O NET
#2
1
2
3
ON
4
5
1
2
3
ON
4
5
1
2
3
ON
4
5
1
2
3
ON
4
5
ON
1
2
3
4
5
AD #1
AD #2
AD #3
AD #4
1
2
3
ON
4
5
1
2
3
ON
4
5
1
2
3
ON
4
5
1
2
3
ON
4
5
ON
1
2
3
4
5
AD #1
AD #2
AD #3
AD #4
Wiring Diagram #8
3/25/99