Operation and Description of Function Settings
Chore-Tronics Feeder Control
18
MT1559A
10/6/99
Feeder System Fill 1
1. Feeder System Fill 1 - this indicates that you are in the Feeder System Fill 1
screen.
2. Events - the events are editable up to 24 events. Only those number of events will
show below.
3. Editable fields to insert start time. All zeros in either column will eliminate event.
4. If a twelve hour clock is selected, an “a” or “p” must be selected.
5. Run for - this indicates the length of time you want this function to run.
Figure 9. Feeder System Fill 1 screen
FEEDER FILL 1 EVENTS = 1
Start Run for
1. 04:00p 01:00:00
1
2
3
4
5
3/25/99