31
LAMPS BY THE ENDS ONLY. NEVER TOUCH THE GLASS WITH BARE HANDS.
WIPE ANY FINGERPRINTS FROM LAMPS WITH ALCOHOL.
QUARTZ SLEEVES ARE SHIPPED WITH SMALL RUBBER STOPS AT THE
BOTTOM OF THE SLEEVE. THIS RUBBER STOP MUST REMAIN IN PLACE TO
PREVENT DAMAGE FROM LAMP INSTALLATION.
Unplug the unit from the power source to prevent the risk of electric shock or system
damage. Isolate the chamber from the pool circulation system by closing the inlet and
outlet valves and opening the bypass valve. Drain the chamber. Loosen the liquid tight
gland and remove the viewing cap. Lift the lamp out of the quartz sleeve without
disconnecting it from the wiring harness. Once the lamp is completely free of the quartz
sleeve it can be safely disconnected from the wiring harness. Remove the quick
disconnect clamp and remove the sleeve from the chamber.
NOTE: If the power supply is within 5 feet of the UV chamber, the quartz sleeve may be
removed without disconnecting or removing the lamp.
WARNING
Read all cautions and directions provided with the muriatic acid used. Always add acid
to water. Use only with adequate ventilation. If strong odor is noticed, STOP, ventilation
is inadequate. Leave area immediately. If the work area is not well ventilated you MUST
use a properly fitted and maintained NIOSH approved respirator for acid fumes.
Clean the quartz sleeve by wiping with a clean cotton cloth and a standard glass
cleaner. Sleeves with calcium accumulation will require cleaning with a 5:1 water and
muriatic acid solution.
Check the gasket on the quartz sleeve quick disconnect flange. Carefully lower the
quartz sleeve assembly into the chamber. On stainless chambers for SAG480 through
SAG1200 the quartz sleeves sit on top of spring assemblies. Quartz sleeves must be
carefully lined up with the spring or damage to the sleeve may occur. (see page 24 for
details) Gently press the quartz sleeve into place and install the quick disconnect clamp
to secure the sleeve in place.
Remove the UV sensor from the chamber and carefully remove the quartz window.
Clean the quartz window by wiping with a clean cotton cloth and standard glass cleaner.
Windows with calcium accumulation will require cleaning with a 5:1 water and muriatic
acid solution. Reinstall the window and sensor. On models without the quartz window,
clean the quartz on the face of the monitor.