Cleaning Quartz Sleeve and UV Monitor Window Chemically (NSF Models)
Unplug the unit from the power source to prevent the risk of electric shock or system
damage. Isolate the chamber from the pool circulation system by opening the bypass
valve and closing the inlet and outlet valves. Drain the chamber.
Connect a ChlorKing Acid Washer or other suitable cleaning setup to the chamber. See
examples in
Figure 3.
Water and muriatic acid are mixed in the cleaning solution tank
at a ratio of 5:1. Five parts water to one part muriatic acid. Flush the chamber for 2 to 5
minutes with cleaning solution. Drain the cleaning solution from the chamber. When
using the ChlorKing Acid Wash System the solution is pumped back into the cleaning
solution tank for reuse. Remove the cleaning solution hoses from the chamber and
close the cleaning solution valves. Open the inlet and out valves to restore pool
circulation to the chamber.