ChipBLASTER Inc
27
14.0. PREVENTATIVE MAINTENANCE (Cont.):
14.3. OIL CHANGE PROCEDURE (Cont.):
14.3.5.
After oil is drained from pump reinstall the plug in back of pump. Torque to 20
Nm (180 In LB).
PROPERLY DISPOSE OF OIL PER LOCAL REGULATIONS.
DO NOT REUSE OIL.
14.3.6. Locate High Pressure Pump fill opening (ON TOP OF PUMP) Place a funnel,
with flexible spout, into opening.
!
FUNNEL W/
FLEX SPOUT
14.3
OIL FILL
OPENING