200 Series General Purpose Vector AC Drive Chapter 5 Functional Parameter Simple List
41
1: Upper limit frequency set by analogue V1
2: Upper limit frequency set by analogue V2
F3-20
Generator torque digit
setting ( rotation speed
control)
50.0
~
300.0%
140.0%
√
F3-21
Torque control forward
maximum frequency
0.00Hz
~
Maximum frequency
50.00Hz
√
F3-22
Torque control reserve
maximum frequency
0.00Hz
~
Maximum frequency
50.00Hz
√
F3-23 Start torque setting
-200.0%
~
200.0%(valid when torque control)
0.0%
√
F3-24
Starting torque holding
time
0.000s
~
5.000s(Valid when torque control)
0.000s
√
F3-25
Torque specified
acceleration time
0.00s
~
320.00s
0.01s
√
F3-26
Torque specified
deceleration time
0.00s
~
320.00s
0.01s
√
F3-27
Torque frequency
acceleration time
0.00s
~
320.00s
3.0s
√
F3-28
Torque frequency
deceleration time
0.00s
~
320.00s
3.0s
√
F3-29
VC over voltage stall
gain
0
~
300
10
√
F3-45
Vector over excitation
gain
80.0%
~
150%
125%
√
F3-46
Excitation adjustment
proportional gain
1
~
32000
500
√
F3-47
Excitation adjustment
integral gain
1
~
32000
250
√
F3-48
Torque adjustment
proportional gain
1
~
32000
500
√
F3-49
Torque adjustment
integral gain
1
~
32000
250
√
Group F4: Input Signal Group
F4-00
S1 terminal function
selection
00: No function
01: Forward running
02: Reserve running
03: 3-wire operation control
04: Jog forward
05: Jog reverse
06: Free parking for all the channels
07: Fault reset
08: External fault input
1 ×
*
F4-01
S2 terminal function
selection
2 ×
*
F4-02
S3 terminal function
selection
7 ×
F4-03
S4 terminal function
selection
0 ×
F4-04 S5 terminal function
0
×