If the following conditions should occur:
-
the cable or the integrated power board on the back show signs of wear or
damage
-
liquid has entered the unit
-
the unit has been left out under the rain
unplug the unit and contact the CHINESPORT SpA technical assistance department.
E
E
L
L
E
E
C
C
T
T
R
R
O
O
M
M
A
A
G
G
N
N
E
E
T
T
I
I
C
C
I
I
N
N
T
T
E
E
R
R
F
F
E
E
R
R
E
E
N
N
C
C
E
E
The ARTIPRESS pressure therapy equipment has been designed and built in
compliance with current DIRECTIVES on ELECTROMAGNETIC
COMPATIBILITY 2014/30/UE with the aim of providing reasonable protection
from damaging interference in residential and health related installations .
All required measurements and tests have been carried out in external specialised
institutes.
Customers may view the EMC measurement reports, upon request at the company.
Due to its operating principle, the ARTIPRESS pressure therapy equipment does not
generate significant radiofrequency energy and it has a sufficient immunity level to
radiating electromagnetic fields: therefore it does not detrimentally interfere with
radioelectric communications; electro-medical equipment for monitoring, diagnosis,
therapy and surgery; office electronic devices such as computers, printers,
photocopiers, fax machines, etc; or any electric or electronic equipment used in
these environments, as long as said equipment complies with the
ELECTROMAGNETIC COMPATIBILITY directive.
In any case, in order to avoid any interference problems, we recommend that you
operate the therapy equipment far enough away from critical equipment for
monitoring vital patient functions, and to be careful when applying therapy to
patients with pacemakers.
T
T
R
R
O
O
U
U
B
B
L
L
E
E
S
S
H
H
O
O
O
O
T
T
I
I
N
N
G
G
C
C
H
H
A
A
R
R
T
T
PROBLEM CAUSE
POSSIBLE SOLUTION
Front panel LCD
display doesn’t
come on: The
equipment doesn’t
work.
Mains plug not plugged in
properly.
Check that the mains socket is
working.
Mains cable not properly
connected to the back
connector on the equipment.
Plug in properly and connect
cable to the back connector of
the equipment.
Mains cable worn or blocked.
Replace the mains cable.
Interruttore posteriore spento.
Switch on the mains switch
Fuse or fuses defective or
blown.
Substitute the missing,
defective or blown fuses.
Back switch off.
Contact the CHINESPORT
SpA assistance centre..
Electronic control circuit
malfunction.
No mains voltage.
Front panel display
doesn’t come on .
Defective components in the
electronic control board..
Contact the CHINESPORT
SpA assistance centre..
Some commands on
the front control
panel are not
working properly.
Defective keys or buttons.
Contact the CHINESPORT
SpA assistance centre..
Electronic control system
malfunction.
The equipment turns
on but the pressure
supply is not
functioning .
Defective connections in the
output pneumatic circuit
connected to the KIT POINT.
Carefully check the condition
of the output connections.
Output cable blocked,
clogged, or damaged.
Set up the KIT-POINT in such
a way as to avoid blockage of
the parts subject to inflation,
the tubes, and the points of
interconnection.
Output tubes connected to the
applicator element (foot, leg,
body-belt, glove, arm-band)
that are damaged at the
interconnecting points.
Check the fast insert
connections .
Replace any defective sectors
with clear signs of wear.
Incorrect turning on, setting,
or starting up of the
equipment.
Check that the equipment
settings are correct.